100W Single Output without PFC Function
ꢏꢃꢆꢍꢌꢄꢃꢅꢈꢔ
�ꢀꢁꢂꢃꢄꢅꢆꢇꢈꢉꢊꢈꢁꢀꢋꢌꢍꢈꢎꢈꢏꢌꢇꢇꢈꢄꢆꢀꢐꢃ
ꢑꢄꢒꢍꢃꢓꢍꢁꢒꢀꢅꢔꢕꢖꢒꢄꢍꢈꢓꢁꢄꢓꢌꢁꢍꢎꢗꢂꢃꢄꢈꢇꢒꢆꢘꢎꢗꢂꢃꢄꢈꢂꢒꢇꢍꢆꢐꢃ
ꢊꢒꢒꢇꢁꢀꢐꢈꢙꢚꢈꢛꢄꢃꢃꢈꢆꢁꢄꢈꢓꢒꢀꢂꢃꢓꢍꢁꢒꢀ
ꢜꢝꢝꢞꢈꢛꢌꢇꢇꢈꢇꢒꢆꢘꢈꢙꢌꢄꢀꢟꢁꢀꢈꢍꢃꢅꢍ
ꢏꢁꢠꢈꢅꢡꢁꢍꢓꢖꢁꢀꢐꢈꢛꢄꢃꢢꢌꢃꢀꢓꢚꢈꢆꢍꢈꢜꢣꢤꢥꢦꢧ
ꢣꢈꢚꢃꢆꢄꢅꢈꢡꢆꢄꢄꢆꢀꢍꢚ
SPECIFICATION
MODEL
LPS-100-3.3 LPS-100-5 LPS-100-7.5 LPS-100-12 LPS-100-13.5 LPS-100-15 LPS-100-24 LPS-100-27 LPS-100-48
DC�VOLTAGE
3.3V
5V
7.5V
12V
13.5V
15V
24V
27V
48V
RATED�CURRENT
CURRENT�RANGE
RATED�POWER
20A
20A
13.3A
8.4A
7.5A
6.7A
4.2A
3.8A
2.1A
0�~�20A
66W
0�~�20A
100W
100mVp-p
4.5�~�5.7V
3.0%
0�~�13.3A
99.75W
100mVp-p
6�~�9V
2.0%
0�~�8.4A
100.8W
100mVp-p
0�~�7.5A
101.25W
100mVp-p
0�~�6.7A
100.5W
100mVp-p
0�~�4.2A(6A 10s) 0�~�3.8A
100.8W(144W�10s) 102.6W
0�~�2.1A
100.8W
200mVp-p
41�~�56V
1.0%
RIPPLE�&�NOISE�(max.) Note.2 150mVp-p
VOLTAGE ADJ.�RANGE
VOLTAGE�TOLERANCE Note.3 3.0%
150mVp-p
150mVp-p
OUTPUT
3�~�3.6V
10�~�13.2V 12�~�15V
13.5�~�18V 20�~�26.4V 26�~�32V
2.0%
0.5%
1.5%
2.0%
0.5%
1.5%
2.0%
0.5%
1.5%
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
LINE�REGULATION
LOAD�REGULATION
SETUP,�RISE�TIME
HOLD�TIME (Typ.)
0.5%
2.0%
0.5%
0.5%
0.5%
2.0%
1.5%
0.5%
800ms,�50ms/230VAC����������1200ms,�50ms/115VAC�at�full�load
26ms/230VAC����������26ms/115VAC�at�full�load
88�~�132VAC�/�176�~�264VAC�auto�switch����������248�~�370VDC
47�~�63Hz
VOLTAGE�RANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
69%
77%
77%
79%
79%
80%
80%
81%
81%
INPUT
2.3A/115VAC����������1.5A/230VAC
AC�CURRENT (Typ.)
INRUSH�CURRENT (Typ.)
COLD�START 20A/115VAC����������40A/230VAC
<1mA /�240VAC
LEAKAGE�CURRENT
105�~�140%�(+24V:�above�6.5A) rated�output�power
OVER�LOAD
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
3.8�~�4.45V 5.75�~�6.75V 9.4�~�10.9V 13.8�~�16.2V 15.5�~�18.2V 18�~�21V
Protection�type�: Hiccup�mode,�recovers�automatically�after�fault�condition�is�removed
-10�~�+60 (Refer�to�output�load�derating�curve)
PROTECTION
27.6�~�32.4V 33.7�~�39.2V 57.6�~�67.2V
OVER�VOLTAGE
WORKING�TEMP.
20�~�90%�RH�non-condensing
WORKING�HUMIDITY
-20�~�+85 ,�10�~�95%�RH
ENVIRONMENT STORAGE�TEMP.,�HUMIDITY
TEMP.�COEFFICIENT
0.05%/ (0�~�50
10�~�500Hz,�2G�10min./1cycle,�Period�for�60min.each�along�X, Y,�Z�axes
UL60950-1, TUV�EN60950-1 Approved
VIBRATION
SAFETY STANDARDS
WITHSTAND�VOLTAGE
I/P-O/P:3KVAC�����I/P-FG:1.5KVAC�����O/P-FG:0.5KVAC
ISOLATION�RESISTANCE
SAFETY &
I/P-O/P,�I/P-FG,�O/P-FG:100M�Ohms/500VDC
Compliance�to�EN55022�(CISPR22)�Class�B
EMI�CONDUCTION�&�RADIATION
HARMONIC�CURRENT
EMC
(Note�4)
Compliance�to EN61000-3-2,-3
EMS�IMMUNITY
MTBF
Compliance�to EN61000-4-2,3,4,5,6,11,�Light�industry�level,��criteria A
203.6Khrs�min.������MIL-HDBK-217F�(25
222*62*32mm�(L*W*H)
)
OTHERS
NOTE
DIMENSION
PACKING
0.45Kg;�24pcs/12.5Kg/1.76CUFT
ꢜꢨꢈꢉꢇꢇꢈꢋꢆꢄꢆꢩꢃꢍꢃꢄꢅꢈꢪꢗꢫꢈꢅꢋꢃꢓꢁꢆꢇꢇꢚꢈꢩꢃꢀꢍꢁꢒꢀꢃꢘꢈꢆꢄꢃꢈꢩꢃꢆꢅꢌꢄꢃꢘꢈꢆꢍꢈꢬꢣꢝꢭꢉꢊꢈꢁꢀꢋꢌꢍꢮꢈꢄꢆꢍꢃꢘꢈꢇꢒꢆꢘꢈꢆꢀꢘꢈꢬꢯ ꢒꢛꢈꢆꢩꢙꢁꢃꢀꢍꢈꢍꢃꢩꢋꢃꢄꢆꢍꢌꢄꢃꢨ
ꢬꢨꢈꢰꢁꢋꢋꢇꢃꢈꢱꢈꢀꢒꢁꢅꢃꢈꢆꢄꢃꢈꢩꢃꢆꢅꢌꢄꢃꢘꢈꢆꢍꢈꢬꢝꢲꢦꢧꢈꢒꢛꢈꢙꢆꢀꢘꢡꢁꢘꢍꢖꢈꢙꢚꢈꢌꢅꢁꢀꢐꢈꢆꢈꢜꢬꢳꢈꢍꢡꢁꢅꢍꢃꢘꢈꢋꢆꢁꢄꢟꢡꢁꢄꢃꢈꢍꢃꢄꢩꢁꢀꢆꢍꢃꢘꢈꢡꢁꢍꢖꢈꢆꢈꢝꢨꢜꢌꢛꢈꢱꢈꢤꢴꢌꢛꢈꢋꢆꢄꢆꢇꢇꢃꢇꢈꢓꢆꢋꢆꢓꢁꢍꢒꢄꢨ
ꢣꢨꢈꢫꢒꢇꢃꢄꢆꢀꢓꢃꢈꢔꢈꢁꢀꢓꢇꢌꢘꢃꢅꢈꢅꢃꢍꢈꢌꢋꢈꢍꢒꢇꢃꢄꢆꢀꢓꢃꢮꢈꢇꢁꢀꢃꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢈꢆꢀꢘꢈꢇꢒꢆꢘꢈꢄꢃꢐꢌꢇꢆꢍꢁꢒꢀꢨ
ꢤꢨꢈꢫꢖꢃꢈꢋꢒꢡꢃꢄꢈꢅꢌꢋꢋꢇꢚꢈꢁꢅꢈꢓꢒꢀꢅꢁꢘꢃꢄꢃꢘꢈꢆꢈꢓꢒꢩꢋꢒꢀꢃꢀꢍꢈꢡꢖꢁꢓꢖꢈꢡꢁꢇꢇꢈꢙꢃꢈꢁꢀꢅꢍꢆꢇꢇꢃꢘꢈꢁꢀꢍꢒꢈꢆꢈꢛꢁꢀꢆꢇꢈꢃꢢꢌꢁꢋꢩꢃꢀꢍꢨꢈꢫꢖꢃꢈꢛꢁꢀꢆꢇꢈꢃꢢꢌꢁꢋꢩꢃꢀꢍꢈꢩꢌꢅꢍ ꢙꢃꢈꢄꢃꢟꢓꢒꢀꢛꢁꢄꢩꢃꢘꢈꢍꢖꢆꢍꢈꢁꢍꢈꢅꢍꢁꢇꢇꢈꢩꢃꢃꢍꢅ
ꢵꢲꢊꢈꢘꢁꢄꢃꢓꢍꢁꢂꢃꢅꢨ
ꢯꢨꢈꢶꢛꢈꢍꢖꢃꢈꢁꢀꢋꢌꢍꢈꢄꢆꢀꢐꢃꢈꢷꢯꢭꢟꢷꢸꢭꢮꢈꢍꢖꢃꢈꢒꢌꢍꢋꢌꢍꢈꢇꢒꢆꢘꢈꢁꢅꢈꢓꢖꢆꢀꢐꢃꢘꢈꢛꢄꢒꢩꢈꢝꢉꢟꢄꢆꢍꢃꢘꢈꢇꢒꢆꢘꢮꢈꢫꢖꢃꢄꢃꢈꢡꢁꢇꢇꢈꢙꢃꢈꢄꢃꢘꢌꢓꢃꢘꢈꢬꢝꢭꢈꢛꢒꢄꢈꢜꢅꢃꢓꢒꢀꢘꢈꢹꢺꢑꢕꢟꢜꢝꢝꢟꢬꢤꢻꢨ
ꢼꢨꢈꢲꢒꢌꢀꢍꢁꢀꢐꢈꢖꢒꢇꢃꢅꢈꢲꢜꢈꢆꢀꢘꢈꢲꢬꢈꢅꢖꢒꢌꢇꢘꢈꢙꢃꢈꢐꢄꢒꢌꢀꢘꢃꢘꢈꢛꢒꢄꢈꢈꢵꢲꢶꢈꢋꢌꢄꢋꢒꢅꢃꢅꢨ
300 Myꢁeꢀ standiꢀh Bꢁvd., Taunton, MA 02780
WWW.AsTRODYNE.COM
ph: 1-800-823-8082
Fax: 508-823-8181