General Purpose Relays
SCHRACK
Miniature Power Relay LN / LNH
n
n
n
n
n
n
1 pole 10 A / 16 A, 1 CO or 1 NO contact
High performance 10 A version (LN1)
16 A High capacity version available (LN3)
Version for HOT-applications (LNH)
Flux proof
Plastic materials according to IEC60335-1 (domestic appliances)
Applications
F0278-B
Domestic appliances
Approvals
V
REG.-Nr. 40004596,
Z
E214025
Technical data of approved types on request
Contact data
LN1
LN3
LNH
Contact configuration
1 CO or 1 NO
single contact
micro disconnection
250 / 400 VAC
16 A1)
Contact set
Type of interruption
Rated voltage / max. switching voltage AC
Rated current
Maximum breaking capacity AC
Limiting making capacity, max 4 s, df 10%
Contact material
10 A
10 A
2500 VA
2500 VA
4000 VA
35 A
AgSnO2
AgSnO2
AgSnO2
(AgCdO)
Rated frequency of operation with / without load
Operate- / release time DC coil
Bounce time DC coil, NO / NC contact
30/300 min-1
max 12 / 6 ms
max 3 / 20 ms
Contact ratings
Type Contact Load
Ambient
Cycles
temp. [°C]
IEC 61810
LN133 NO
LN333 NO
LNH33 NO
LNH33 NO
UL 508
10 A, 250 VAC, cosϕ=1
16 A, 250 VAC, cosϕ=1
10 A, 250 VAC, cosϕ=1
8 A, 250 VAC, cosϕ=1
85°C
85°C
105°C
105°C
250x103
50x103
200x103
250x103
LN1
LN3
NO
NO
NO
10 A, 250 VAC, general purpose
16 A, 250 VAC, general purpose
10 A, 250 VAC, resistive
85°C
85°C
85°C
200x103
50x103
LNH
200x103
1)
For 16 A at 85°C: coil power reduction to 50% necessary
For 16 A with 100% coil power: max. ambient temperature 75°C
For 100% coil power at 85°C: max. contact current 15 A
Coil data
Rated coil voltage range DC coil
Operative range to IEC 61810
LN1
5...48 VDC
2
LN3
5...48 VDC
2
LNH
5...48 VDC
Operative voltage range, % of rated coil voltage
Coil insulation system according UL1446
90 - 110%
class F
class F
class F
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
Product specification
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
otherwise specified and are
shown for reference purposes
only.
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
Specifications subject to
change.