描述
Liquid Flow Switch and Bubble Detector

LG01-2000A090 数据手册

 浏览型号LG01-2000A090的Datasheet PDF文件第2页浏览型号LG01-2000A090的Datasheet PDF文件第3页浏览型号LG01-2000A090的Datasheet PDF文件第4页 
LG01-2000Axxx  
Liquid Flow Switch and Bubble Detector  
. Detection of low liquid flow in the ml/min Range  
. Totally non-invasive  
. Ultra-fast response time of 100 ms  
Product Summary  
The LG01 Liquid Flow Switch enables detection of  
flow of liquid in the range of ml/min. The output signal  
is 5V when the flow rate is higher than the specified  
flow switch point and 0V below this limit or when air  
or bubbles are found inside the sensors flow channel  
instead of liquid.  
Excellent chemical resistance and bio-compatibility  
are ensured: The flow path of the LG01 Liquid Flow  
Switch is formed by a simple, straight glass capillary.  
For more information on communication, please refer  
to section 2 of this document.  
1 Sensing Performance  
Table 1: Model specific performance of LG01 (all data for medium H2O, 23°C)  
Parameter  
LG01-2000A090  
LG01-2000A005  
Unit  
H2O flow switching point  
H2O maximum flow rate  
Accuracya of switching point  
Switching hysteresis  
4.5  
50  
0.25  
220  
±10  
±5  
ml/min  
ml/min  
±10  
±5  
% of switching point  
% of switching point  
Mounting orientation sensitivityb  
Flow detection response time 63  
Response time on power-up  
Operating temperature  
Ambient storage temperaturec  
Operating pressure  
+2  
+14  
% of switching point  
50  
ms  
ms  
°C  
120  
+10…+50  
-10…+60  
°C  
3
5
bar  
bar  
Proof pressure  
aBetter available on request  
bMaximum shift of switching point if mounted vertically  
cNon-condensing, flow path empty  
1.1 Operation with Other Liquids than Water  
Due to the measurement principle the LG01 flow switch characteristics is changing with the thermal properties of the  
liquid. For aqueous solutions the data for H2O as stated above is a good approximation.  
For hydrocarbon liquids such as oil, fuel, or organic solvents, the flow switch point shifts towards higher flow rates.  
For indicative purpose, data is provided for isopropyl alcohol (IPA) below.  
Table 2: Approximate switch levels of the LG01 liquid flow switch with hydrocarbon liquids  
Parameter  
LG01-2000A090  
LG01-2000A005  
Unit  
Approximate flow switching point with IPA  
Maximum flow rate with IPA  
9
1.4  
ml/min  
ml/min  
>250  
>250  
www.sensirion.com  
February 2015 V2  
1/4  

与LG01-2000A090相关器件

型号 品牌 获取价格 描述 数据表
LG016M12K0BPF-3025 YAGEO

获取价格

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 16V, 20% +Tol, 20% -Tol, 12000
LG0201 ETC

获取价格

LG-020WK-DT LIGITEK

获取价格

LED SMD
LG-020WK-DT-J LIGITEK

获取价格

LED SMD
LG-020WK-DT-J-N1 LIGITEK

获取价格

LED SMD
LG-020WK-DT-J-N12 LIGITEK

获取价格

LED SMD
LG-020WK-DT-N12 LIGITEK

获取价格

LED SMD
LG-020WKZ-DT LIGITEK

获取价格

LED SMD
LG-020WKZ-DT-N12 LIGITEK

获取价格

LED SMD
LG0301 ETC

获取价格