Ordering information
AC-DC Power Supplies Open Frame/ Enclosed Type
LEP 100
F
-24 -O
LEP100F
1ꢀ
2ꢀ
3ꢀ
4ꢀ
5
1Series name
2Output wattage
3Universal input
Example recommended EMI/EMC filter
NAC-06-472
R
4Output voltage
5Optional *1 *6
G :Low leakage current
R :with Remote ON/OFF
S :with Chassis
SN:with Chassis & cover
T :Vertical terminal block
U :Operating stop voltage
is set at a lower value
Z :with ZT
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
Aꢀhigher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
MODEL
LEP100F-24
LEP100F-36
LEP100F-48
(
)
(
)
(
)
DC OUTPUT
+24V 4.2 Peak 7 A
+36V 2.8 Peak 4.7 A
+48V 2.1 Peak 3.5 A
SPECIFICATIONS
MODEL
LEP100F-24
LEP100F-36
LEP100F-48
VOLTAGE[V]
AC85 - 264 1 or DC 120 - 370
f
(
(
)
)
ACIN 100V 1.4typ Io=100%
CURRENT[A]
ACIN 200V 0.7typ Io=100%
( )
50/60 47 - 63 or DC
FREQUENCY[Hz]
(
(
)
)
(
(
)
)
(
83typ Io=100%
)
)
ACIN 100V 81typ Io=100%
82typ Io=100%
EFFICIENCY[%]
INPUT
(
ACIN 200V 84typ Io=100%
85typ Io=100%
85typ Io=100%
(
(
)
)
ACIN 100V 0.98typ Io=100%
POWER FACTOR
ACIN 200V 0.93typ Io=100%
(
(
) (
) (
) (
) (
)
)
ACIN 100V 15typ Io=100% At cold start Ta=25
C
C
INRUSH CURRENT[A]
ACIN 200V 30typ Io=100% At cold start Ta=25
(
,
)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
0.75max 60Hz According to IEC60950 and DEN-AN
+24 +36
0 - 2.8 Peak 4.7
+48
2
*
(
)
(
)
(
)
0 - 4.2 Peak 7
0 - 2.1 Peak 3.5
(
)
(
)
(
)
WATTAGE[W]
LINE REGULATION[mV]
LOAD REGULATION[mV]
100.8 Peak 168
48max
100.8 Peak 169.2
48max
100.8 Peak 168
48max
76max
90max
150max
150max
300max
250max
350max
240max
300max
48max
3
3
3
3
0 to +50
*
*
*
*
120max
160max
150max
180max
120max
145max
48max
120max
160max
150max
180max
150max
180max
48max
C
RIPPLE[mVp-p]
-10 - 0
C
0 to +50
C
OUTPUT
RIPPLE NOISE[mVp-p]
-10 - 0
C
0 to +50
-10 to +50
C
TEMPERATURE REGULATION[mV]
C
4
*
DRIFT[mV]
(
,
)
START-UP TIME[ms]
HOLD-UP TIME[ms]
500max ACIN 100V Io=100%
(
,
)
20typ ACIN 100V Io=100%
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 21.4 - 26.4
OUTPUT VOLTAGE SETTING[V] 23.0 - 25.0
26.4 - 39.6
35.0 - 37.0
39.6 - 52.8
46.0 - 50.0
OVERCURRENT PROTECTION Works over 101% of peak current and recovers automatically
CIRCUIT AND OVERVOLTAGE PROTECTION Works at 115 - 140% of rating
PROTECTION
OTHERS
( )
Option Refer to Instruction Manual
REMOTE ON/OFF
5
*
, , , (
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
INPUT-OUTPUT RC
INPUT-FG
-
, , , (
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature
W
)
ISOLATION
5
5
, , (
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature
W
)
OUTPUT RC-FG
OUTPUT-RC
*
-
, , (
AC100V 1minute Cutoff current = 100mA DC100V 10M min At Room Temperature
W
)
*
,
,
(
) (
),
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +70
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet max
C
,
,
(
),
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75
20 - 90%RH Non condensing 9 000m 30 000feet max
2
C
ENVIRONMENT
,
(
),
,
,
VIBRATION
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis
(
,
,
IMPACT
196.1m/s2 20G 11ms once each X Y and Z axis
),
,
(
)
,
,
,
(
)
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
UL60950-1 C-UL CSA60950-1 EN60950-1 EN60065 EN50178 Complies with DEN-AN and IEC60950-1 At only AC input
SAFETY AND
NOISE
,
,
,
Complies with FCC-B CISPR22-B EN55022-B VCCI-B
Complies with IEC61000-3-2
( )
75 35 222mm [2.95 1.38 8.74 inches] W H D
X X
REGULATIONS
7
*
(
)
/380g max with chassis & cover : 650g max
X
X
X
X
OTHERS
Convection
*1 Specification is changed at option, refer to Instruction Manual 6.
*2 Peak loading for 10sec. And Duty 35% max, refer to Instruction Manual 5. In detail.
*3 This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*5 Applicable when remote control (optional) is added.
*6 Please contact us about safety approvals for the model with option.
*7 Please contact us about class C.
*
*
*
Parallel operation with other model is not possible.
Derating is required when operated with chassis and cover.
A sound may occur from power supply at peak loading.
*4 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
M arch 13, 2019
LEP-2