Thin-Film RF/Microwave Inductor Technology
Accu-L® Series
L0603 AND L0805 SMD High-Q RF Inductor – Accu-L®
HOW TO ORDER
L
0805
4R7
D
E
S
TR
Packaging
Code
Product
Size
0603
0805
Inductance
Expressed in nH
(2 significant digits
+
Tolerance
for
L ≤ 4.7nH,
B = ±0.1nH
C = ±0.2nH
D = ±0.5nH
Specification
Termination
Code
Sn100
Code
E = Accu-L® 0805
technology
TR = Tape and Reel
W = Nickel/
(3,000/reel)
solder coated
(Sn 63, Pb 37)
G = Accu-L® 0603
technology
number of zeros)
for
Not RoHS Compliant
**S= Nickel/Lead
values <10nH,
letter R denotes
decimal point.
Example:
22nH = 220
4.7nH = 4R7
Free
Solder coated
(Sn100)
4.7nH<L<10nH,
C = ±0.2nH
D = ±0.5nH
**RoHS compliant
LEAD-FREE COMPATIBLE
COMPONENT
L ≥ 10nH,
G = ±2%
J = ±5%
For RoHS compliant products,
please select correct termination style.
Engineering Kits Available see
pages 118-119
ELECTRICAL SPECIFICATIONS TABLE FOR ACCU-L® 0603
450 MHz
900 MHz
1900 MHz
2400 MHz
I
max.
D(CmA)
Test Frequency
Test Frequency
Test Frequency
Test Frequency
SRF min.
(MHz)
R
DC max.
(Ω)
Inductance
L (nH)
Available
Inductance Tolerance
Q
Q
Q
(1)
L (nH)
L (nH)
L (nH)
Q Typical
Typical
Typical
Typical
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10.0
12.0
15.0
±0.1, ±0.2nH
±0.1, ±0.2nH
±0.1, ±0.2nH
±0.1, ±0.2nH
±0.1, ±0.2nH
±0.1, ±0.2, ±0.5nH
±0.1, ±0.2, ±0.5nH
±0.1, ±0.2, ±0.5nH
±0.2, ±0.5nH
±0.2, ±0.5nH
±0.2, ±0.5nH
±2%, ±5%
49
26
20
20
21
24
25
23
26
23
23
28
28
28
1.2
70
1.2
1.52
1.73
2.24
2.75
3.39
4.06
4.92
5.94
7.3
134
1.2
170
10000
10000
10000
10000
9000
8400
6500
5500
5000
4500
3800
3500
3000
2500
0.04
0.06
0.07
0.08
0.08
0.08
0.12
0.15
0.25
0.30
0.35
0.45
0.50
0.60
1000
1000
1000
1000
750
750
500
500
300
300
300
300
300
300
1.54
1.74
2.2
2.7
3.33
3.9
4.68
5.65
6.9
8.4
10
39
30
30
30
35
57
32
36
33
31
39
38
38
63
50
49
48
56
60
46
54
47
35
47
30
30
1.52
1.72
2.24
2.79
3.47
4.21
5.2
6.23
8.1
12.1
14.1
17.2
49.8
76
59
56
54
64
69
49
60
39
31
41
20
15
10
11.8
14.1
25.9
±2%, ±5%
±2%, ±5%
13.2
16.2
(1) IDC measured for 15°C rise at 25°C ambient temperature when soldered to FR-4 board.
Inductance and Q measured on Agilent 4291B / 4287 using the 16196A test fixture.
ELECTRICAL SPECIFICATIONS TABLE FOR ACCU-L® 0805
450 MHz
900 MHz
1900 MHz
2400 MHz
Test Frequency
I
max.
Test Frequency
Test Frequency
Test Frequency
D(CmA)
SRF min.
(MHz)
R
DC max.
(Ω)
Inductance L
(nH)
Available Inductance Tolerance Q Typical L (nH) Q Typical L (nH) Q Typical L (nH) Q Typical
T = 15°C (1) T = 70°C (2)
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.1nH, ±0.2nH, ±0.5nH
±0.5nH
60
50
50
42
42
38
27
43
50
43
43
46
40
36
30
36
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.8
5.7
92
74
72
62
62
46
36
62
68
62
56
60
50
46
27
33
1.2
1.5
1.8
2.2
2.8
3.4
4.0
5.3
6.3
7.7
10.0
13.4
17.3
27
122
102
88
82
80
48
38
76
73
71
55
52
40
23
–
1.2
1.5
1.9
2.3
2.9
3.5
4.1
5.8
7.6
9.4
15.2
–
92
84
73
72
70
57
42
60
62
50
32
–
10000
10000
10000
10000
10000
10000
10000
5500
4600
4500
3500
2500
0.05
0.05
0.06
0.07
0.08
0.11
0.20
0.10
0.10
0.11
0.12
0.13
0.20
0.20
0.35
0.40
1000
1000
1000
1000
1000
750
750
750
750
750
750
750
750
750
500
500
2000
2000
2000
2000
2000
1500
1500
1500
1500
1500
1500
1500
1500
1000
1000
1000
±0.5nH
±0.5nH
±2%, ±5%
±2%, ±5%
±2%, ±5%
±2%, ±5%
±2%, ±5%
7.0
8.5
10.6
12.9
16.7
21.9
27.5
12
15
18
22
–
–
–
–
–
–
–
–
2400
2200
1700
1400
–
–
–
(1) IDC measured for 15°C rise at 25°C ambient temperature
(2) IDC measured for 70°C rise at 25°C ambient temperature
L, Q, SRF measured on HP 4291A, Boonton 34A and Wiltron 360 Vector
Analyzer, RDC measured on Keithley 580 micro-ohmmeter.
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or
available online at www.avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
42
111120