KSN-1060A-119+
Frequency Synthesizer
Typical Performance Data
FREQUENCY
(MHz)
POWER OUTPUT
VCO CURRENT
(mA)
PLL CURENT
(mA)
(dBm)
+25°C
0.64
0.62
0.62
0.65
0.61
0.48
0.33
0.20
0.10
-0.05
-0.06
-45°C
-0.46
-0.44
-0.39
-0.36
-0.43
-0.58
-0.69
-0.77
-0.79
-0.85
-0.85
+85°C
0.40
0.39
0.40
0.44
0.40
0.24
0.02
-0.24
-0.53
-0.94
-0.96
-45°C
+25°C
36.81
36.85
36.94
37.03
37.11
37.18
37.24
37.27
37.27
37.25
37.25
+85°C
-45°C
14.71
14.46
14.50
14.67
14.72
14.67
14.55
14.47
14.70
14.76
14.74
+25°C
16.01
15.78
15.84
16.02
16.08
16.04
15.91
15.83
16.07
16.14
16.12
+85°C
18.70
18.43
18.47
18.65
18.73
18.68
18.54
18.46
18.71
18.79
18.77
969.99
976.92
34.96
34.98
35.05
35.14
35.22
35.27
35.31
35.34
35.37
35.37
35.37
38.18
38.22
38.29
38.36
38.43
38.50
38.54
38.57
38.60
38.62
38.62
988.86
1000.80
1012.74
1024.68
1036.62
1048.56
1060.50
1072.44
1072.98
FREQUENCY
(MHz)
HARMONICS (dBc)
F2
F3
-45°C
-22.72
-23.08
-23.96
-24.69
-25.25
-25.32
-26.14
-26.63
-27.67
-29.84
-29.99
+25°C
-24.16
-24.20
-24.57
-25.23
-25.59
-25.57
-26.74
-27.51
-28.52
-28.05
-27.96
+85°C
-24.50
-24.48
-24.76
-25.18
-25.44
-25.28
-25.56
-24.52
-23.24
-22.00
-21.96
-45°C
-37.55
-38.13
-39.26
-40.76
-42.48
-43.97
-44.89
-46.67
-47.77
-48.96
-49.04
+25°C
-40.13
-41.28
-42.90
-44.41
-46.18
-47.60
-47.83
-49.69
-50.91
-52.25
-52.43
+85°C
969.99
976.92
-43.42
-44.41
-45.33
-46.39
-47.67
-48.66
-49.33
-51.65
-53.54
-55.29
-55.75
988.86
1000.80
1012.74
1024.68
1036.62
1048.56
1060.50
1072.44
1072.98
®
RoHS compliant
P.O. Box 350166, Brooklyn, New York 11235-0003 (718) 934-4500 Fax (718) 332-4661
The Design Engineers Search Engine finds the model you need, Instantly • For detailed performance specs & shopping online see
IF/RF MICROWAVE COMPONENTS�ꢀ�ꢁꢂꢃ 9001 ISO14001 AS9100 CERTIFIED
TM
Notes: 1. Performance and quality attributes and conditions not expressly stated in this specification sheet are intended to be excluded and do not form a part of this specification sheet. 2. Electrical specifications and
performance data contained herein are based on Mini-Circuit’s applicable established test performance criteria and measurement instructions. 3. The parts covered by this specification sheet are subject to Mini-Circuits
standard limited warranty and terms and conditions (collectively, “Standard Terms”); Purchasers of this part are entitled to the rights and benefits contained therein. For a full statement of the Standard Terms and the
exclusive rights and remedies thereunder, please visit Mini-Circuits’ website at www.minicircuits.com/MCLStore/terms.jsp.
Page 4 of 13