KK74VHC241
DC electrical characteristics
Value
Symbo
VCC,
V
–40
to 85 °C
min max
Unit
25 °C
Parameter
l
Test conditions
min
1.5
max
VIH High input voltage
–
2.0
–
1.5
0.7Vcc
–
–
V
3.0-5.5 0.7Vcc
–
–
VIL Low input voltage
–
2.0
–
0.5
0.5
3.0-5.5
–
0.3Vcc
–
0.3Vcc
VOH High output voltage VI = VIH or VIL 2.0
1.92
2.92
4.42
5.52
–
–
–
–
1.9
2.9
4.4
5.4
–
–
–
–
IO = -50 mkA
3.0
4.5
5.5
VI = VIH or VIL;
IO = -4 mA
VI = VIH or VIL;
IO = -8 mA
3.0
4.5
2.58
3.94
–
–
2.48
3.80
–
–
VOL Low output voltage VI
=
VIH orVIL 2.0
–
–
–
–
0.09
0.09
0.09
0.09
–
–
–
–
0.1
0.1
0.1
0.1
IO = 50 mkA
3.0
4.5
5.5
VI = VIH or VIL
IO = 4 mA
VI = VIH or VIL
IO = 8 mA
3.0
4.5
–
0.36
–
0.44
–
-
0.36
–
-
0.44
IOZ Output current in VI = VIH or VIL 5.5
mkA
±0.25
±2.5
"off" state
VO = VCC or 0V
II
Input current
VI = 5.5V or 0V
0 – 5.5
-
-
-
-
±0.1
4.0
±1.0
40.0
ICC Consumption current VI =VCC or 0V 5.5
4