5秒后页面跳转
JTA2048D03 PDF预览

JTA2048D03

更新时间: 2024-09-27 05:40:23
品牌 Logo 应用领域
XPPOWER /
页数 文件大小 规格书
4页 123K
描述
DC-DC Power Supplies

JTA2048D03 技术参数

是否无铅: 不含铅是否Rohs认证: 符合
生命周期:Active零件包装代码:MODULE
包装说明:, MODULE,7LEAD,1.8针数:8/7
Reach Compliance Code:compliant风险等级:5.74
其他特性:ADDITIONAL -15 VOLT OUTPUT AVAILABLE模拟集成电路 - 其他类型:DC-DC REGULATED POWER SUPPLY MODULE
最大输入电压:75 V最小输入电压:18 V
标称输入电压:48 VJESD-30 代码:R-XDMA-P7
长度:50.8 mm最大负载调整率:2%
功能数量:1输出次数:2
端子数量:7最高工作温度:60 °C
最低工作温度:-40 °C最大输出电流:0.67 A
最大输出电压:16.5 V最小输出电压:13.5 V
标称输出电压:15 V封装主体材料:UNSPECIFIED
封装等效代码:MODULE,7LEAD,1.8封装形状:RECTANGULAR
封装形式:MICROELECTRONIC ASSEMBLY峰值回流温度(摄氏度):NOT SPECIFIED
认证状态:Not Qualified座面最大高度:12.43 mm
子类别:Other Analog ICs表面贴装:NO
技术:HYBRID温度等级:OTHER
端子形式:PIN/PEG端子位置:DUAL
处于峰值回流温度下的最长时间:NOT SPECIFIED最大总功率输出:20 W
微调/可调输出:YES宽度:40.6 mm
Base Number Matches:1

JTA2048D03 数据手册

 浏览型号JTA2048D03的Datasheet PDF文件第2页浏览型号JTA2048D03的Datasheet PDF文件第3页浏览型号JTA2048D03的Datasheet PDF文件第4页 
10-20 Watts  
JTA Series  
xppower.com  
4:1 Input Range  
-40 ˚C to +100 ˚C Operating Temperature  
Single & Dual Outputs  
Overvoltage & Overcurrent Protection  
UL Safety Approvals  
Remote On/Off  
1500 VDC Isolation  
Specification  
Input  
General  
Input Voltage Range  
• 9-36 VDC  
18-75 VDC  
Efficiency  
Isolation  
MTBF  
• See table  
• 1500 VDC Input to Output  
• 1ꢀ000 kHrs min per MIL-HDBK-217F  
Input Current  
• JTA10: 1.65 A max at 9 VDC input  
JTA15: 2.20 A max at 9 VDC input  
JTA20: 2.90 A max at 9 VDC input  
Environmental  
Operating Temperature • -40 ºC to +100 ºCꢀ see derating curve  
Output  
Case Temperature  
Cooling  
• +100 °C max  
Output Voltage  
• See table  
• Natural convection  
• 5-95% RHꢀ non-condensing  
• -55 ºC to +105 ºC  
Output Voltage Trim  
Voltage Balance  
Minimum Load  
10% (15 & 20 W models only)  
Operating Humidity  
Storage Temperature  
1% max dual modelsꢀ 100% load  
• No minimum load required for single  
output modelsꢀ 10% required for dual  
output models  
EMC & Safety  
Emissions  
• EN55022ꢀ  
Line Regulation  
Load Regulation  
1% max  
level A conducted (below -25 ºC)  
level B conducted (-25 ºC to +100 ºC)  
See note 1.  
• Single output models: 1% max  
Dual output models: 2% max  
for a 10-100% load change  
EN55022ꢀ level A radiated  
Setpoint Accuracy  
Ripple & Noise  
2%  
ESD Immunity  
• EN61000-4-2ꢀ level 2  
Perf Criteria A  
• Single output models: 50 mV pk-pk  
Dual output models: 75 mV pk-pk typical  
at 20 MHz BW  
Radiated Immunity  
Conducted Immunity  
Safety Approvals  
• EN61000-4-3 3 V/rmsꢀ  
Perf Criteria A  
Transient Response  
• 4% max deviationꢀ recovery to within  
1% in <500 µs for a 25% load change  
• EN61000-4-6 3 V/mꢀ  
Perf Criteria A  
Temperature  
Coefficient  
• 0.02%/ºC  
• UL60950-1  
Overvoltage Protection • See table  
Overcurrent Protection • Continuous with auto recovery  
Remote On/Off  
• On = Logic High or Open  
Off = Logic Low or <1.8 V  
(15 & 20 W models only)