Revision History—Intel 82599 10 GbE Controller
Date
Revision
Description
Specification Clarifications added or updated:
8/15/2011
2.81
•
6. AN 1G TIMEOUT Only Works When the Link Partner Is Idle (Text in description
corrected.)
•
•
8. PCIe Timeout Interrupt (Added)
9. Master Disable Flow (Added)
Errata added or updated:
•
48. FCoE: Exhausted Receive Context Is not Invalidated if Last Buffer Size Is Equal to
User Buffer Size (Updated Windows* driver information in workaround.)
•
•
50. LED Does not Blink in Invert Mode (Added)
51. LEDs Cannot Be Configured to Blink in LED_ON Mode (Added)
Software Clarifications added or updated:
3. Serial Interfaces Programmed by Bit Banging
•
Device Information added:
9/14/2011
2.82
•
JL82599EN (Single Port; SFI Only). Port 1 disabled. See device information tables; for
example - Table 1-1.
Errata added or updated:
•
•
5. Flow Director Statistics Inaccuracy (Problem statement updated for clarity.)
52. NC-SI: Get NC-SI Pass-Through Statistics Response Format (Added)
Device Information updated:
Table 1-1: S-Specification names were incorrect. These have been corrected.
10/28/2011
12/7/2011
2.83
2.84
•
Specification Clarifications added or updated:
•
5. SFP+ (SFI) Connection Clarification (Note updated. Reference made to workaround
available under NDA.)
Specification Clarifications added or updated:
2/03/2012
2.85
10. Padding on Transmitted SCTP Packets.Errata added or updated:
•
37. PCIe: PM_Active_State_NAK Message Might Be Ignored (New internal-only text
added to the second workaround bullet: “In this case, if 82599 is connected to a x1 or x2
Lane PCIe Link, it might send a PM_Active_State_Request_L1 DLLP with bad CRC and a
Correctable Error will be reported by Upstream Device. See https://vthsd.iil.intel.com/
hsd/hadar/bug_de/default.aspx?bug_de_id=2610409.”)
•
Specification Clarifications added or updated:
11. 82599EN EEPROM Image File (Added)
Specification Changes added or updated:
4. Bit 16 of CTRL_EXT Register Must Be Set (Added)
Errata added or updated:
4/24/2012
2.86
•
•
•
•
53. Flow Director Filters Configuration Issue (Added)
54. PF's MSI TLP Might Contain the Wrong Requester ID When a VF Uses MSI-X (Added)
Software Clarifications added or updated:
•
•
4. Identify Network Adapter Port by Blinking LED (Added)
5. PF/VF Drivers Should Configure Registers That Are not Reset by VFLR (Added)
3