JL
TYPES AND COIL DATA (at 20°C 68°F)
Part No.
Normal
operating
current, mA
(±10%)
Nominal
voltage,
V DC
Pick-up volt-
age,
V DC (max.) V DC (min.)
Drop-out
voltage,
Coil resis-
tance,
Normal
operating
Max. allowable
voltage,
Slim type
Flat type
Ω (±10%)
power, mW (at 60°C 140°F)
JL1aGF-TMP1-5V JL1aZF-TMP1-5V
JL1aGF-TMP1-6V JL1aZF-TMP1-6V
JL1aGF-TMP1-9V JL1aZF-TMP1-9V
JL1aGF-TMP1-12V JL1aZF-TMP1-12V
JL1aGF-TMP1-18V JL1aZF-TMP1-18V
JL1aGF-TMP1-24V JL1aZF-TMP1-24V
5
6
3.5
4.2
0.25
0.3
100
50
72
83.3
55.6
41.7
27.8
20.8
130% of
nominal voltage
(100% of nominal
voltage
at 85°C 185°F)
9
6.3
0.45
0.6
162
500
12
18
24
8.4
288
12.6
16.8
0.9
648
1.2
1,152
REFERENCE DATA
1. Operate/release time
2. Coil temperature rise
3. Ambient temperature characteristics
(Contact carrying current: 16 A)
Sample: JL1aGF-TMP1-12V, 6 pcs.
Sample: JL1aZF-TMP1-12V, 20 pcs.
Ambient temperature: 25°C 77°F
Sample: JL1aGF-TMP1-12V, 5 pcs.
Point measured: inside the coil
Ambient temperature: 26°C 79°F
200
10
Contact carrying current:
16 A 0 A
60
50
40
30
20
10
0
180
Allowable ambient
temperature against %
8
Contact carrying current
16A
13A
8A
160
140
120
100
80
Operate time
coil voltage (max.
set as 115°C
239°F)
0A
6
Max.
x
Pick-up voltage with
hot-start condition of
100%V on the coil.
Min.
4
2
0
Release time
Max.
x
Min.
Pick-up voltage
60
Ambient temperature, °C
0
80
90 100 110 120 130
Coil applied voltage, %V
0
80
90 100 110 120 130
Coil applied voltage, %V
0
20
40
80
4. Life curve
5-(1). Electrical life test
Operation frequency: 20 times/min.
(ON/OFF = 1.5s:1.5s)
Ambient temperature: Room temperature
Sample: JL1aGF-TMP1-12V, 6 pcs.
Load: AC 277 V, 16 A, resistive load
Opetation frequency: 20 cpm
(ON:OFF = 1.5 s:1.5 s)
Change of pick-up and Drop-out voltage
100
12
Ambient temperature : 26°C 79°F
circuit:
10
8
125V AC resistive load
Pick-up voltage
10
6
4
2
0
Max.
x
Welding and
mis-contact
detection
250V AC resistive load
277 V AC
12 V DC
Min.
Drop-out voltage
5
Max.
x
Min.
1
10 11 12 13 14 15 16
Contact current, A
10
NO. of operations, ×104
5-(2). Electrical life test
Sample: JL1aZF-TMP1-12V, 5 pcs.
Load: AC 125 V, 12 A
Opetation frequency: 20 cpm
(ON:OFF = 1.5s:1.5 s)
Change of pick-up and Drop-out voltage
12
Ambient temperature : 80°C 176°F
10
Circuit: (with coil diode protection)
8
Pick-up voltage
Max.
6
4
x
Min.
Welding and
mis-contact
detection
125 V AC
12 V DC
Drop-out voltage
5
2
0
Max.
x
Min.
10
NO. of operations, ×104
103