VDE
8 A POWER RELAY
FEATURES
JG-RELAYS
• Compact & flat design: 22 mm .866 inch (length) × 14 mm .551 inch (width)
× 11.6 mm .457 inch (height)
14
.551
22
.866
• High capacity: 8 A nominal switching capacity
• High surge resistance: Min. 10,000 V between contact and coil
• High sensitivity: 200 mW nominal operating power
• VDE,TÜV, SEMKO also approved
11.6
.457
mm inch
SPECIFICATIONS
Contact
Characteristics
Arrangement
1 Form A
100 mΩ
Max. operating speed
Initial insulation resistance*1
20 cpm
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Min. 100 mΩ at 500 V DC
750 Vrms for 1 min.
Between open contacts
Initial
Contact material
Silver alloy
breakdown
voltage*2
Between contacts and
coil
2,000 Vrms for 1 min.
8 A 125 V AC
5 A 250 V AC
5 A 30 V DC
Nominal switching capacity
Surge voltage between contact and
coil*3
Operate time*4 (at nominal voltage)
Release time*4
(at nominal voltage)(without diode)
Min. 10,000 V
Approx. 5 ms
Approx. 3 ms
Rating
(resistive
load)
Max. switching power
Max. swtiching voltage
Max. switching current
Mechanical (at 180 cpm)
1,250 VA, 150 W
250 V AC, 110 V DC (0.3 A)
8 A (AC), 5A (DC)
5×106
Max. 45°C with nominal coil
voltage and at 8 A contact
current
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
98 m/s2 {10 G}, 10 to 55 Hz
at double amplitude of 1.6 mm
Expected
life (min.
operations)
Temperature rise
(Ambient temperature: 70°C)
Electrical (at 8 A 125 V AC)
(at 20 cpm)
105
Functional*5
Shock resistance
Coil
Destructive*6
Nominal operating power
200 mW
Functional*7
Vibration resistance
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current; 10 mA
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
Destructive
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time
Conditions for operation,
transport and storage*8
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–40°C to +70°C
–40°F to +158°F
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
Humidity
5 to 85% R.H.
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
Unit weight
Approx. 7 g .25 oz
TYPICAL APPLICATIONS
ORDERING INFORMATION
• Microwave ovens
• Small household appliances
• Water heaters
Ex. JG1aF
24V
• Electric irons
• Coffee makers
Coil voltage (DC)
5, 6, 9, 12, 18, 24 V
Note: Standard packing: 100 pcs. Case: 500 pcs.
UL/CSA, VDE approved type is standard.
73