IMP5111/5112
Recommended Operating Conditions2
Parameter
Symbol
Min
Typ
Max
Units
TermPwr Voltage
VTERM
3.3
5.5
VTERM
0.8
V
High Level Enable Input Voltage
Low Level Disable Input Voltage
Operating Junction Temperature Range
IMP5111
IMP5112
IMP5111
IMP5112
VIH
2
V
0
VIL
0
0.8
V
2
VTERM
125
0
°C
5111/5112_t02.eps
Note:
2. Recommended operating conditions indicate the range over which the device is functional.
Electrical Characteristics
Unless otherwise specified, these specifications apply at an ambient operating temperature of TA = 25°C. TermPwr = 4.75V. Low duty cycle
pulse testing techniques are used which maintain junction and case temperatures equal to the ambient temperature.
Parameter
Symbol Conditions
Min
Typ
Max Units
Output High Voltage
VOUT
2.65
2.85
V
TermPwr Supply Current
ICC
All data lines = Open
6
9
mA
All data lines = 0.5V
215
275
275
–23
10
225
µA
IMP5111
IMP5112
DISCONNECT Pin < 0.8V
DISCONNECT Pin > 2.0V
VOUT = 0.5V
Output Current
IOUT
IIN
–21
–24
mA
DISCONNECT Input Current
IMP5111
IMP5112
DISCONNECT Pin = 4.75V
DISCONNECT Pin = 0V
DISCONNECT Pin = 0V
DISCONNECT Pin = 4.75V
DISCONNECT Pin < 0.8V, VO = 0.5V
DISCONNECT Pin > 2.0V, VO = 0.5V
VOUT = 0V, Frequency = 1MHz
nA
µA
–90
–90
10
µA
DISCONNECT Input Current
Output Leakage Current
IIN
nA
nA
IMP5111
IMP5112
IOL
10
10
Capacitance in DISCONNECT Mode
Channel Bandwidth
COUT
BW
3
pF
35
MHz
Termination Sink Current, per Channel
ISINK
VOUT = 4V
60
mA
5111/5112_t03.eps