5秒后页面跳转
HV100DB1 PDF预览

HV100DB1

更新时间: 2022-11-27 00:21:20
品牌 Logo 应用领域
超科 - SUPERTEX 控制器
页数 文件大小 规格书
2页 444K
描述
3-Pin Hotswap Controller

HV100DB1 数据手册

 浏览型号HV100DB1的Datasheet PDF文件第2页 
HV100DB1  
3-Pin Hotswap Controller  
Introduction  
Specifications  
The Supertex HV100DB1 demo board contains all necessay  
circuitry to demonstrate the features of the HV100 hotswap  
controller. Intended primarily as a negative hotswap controller,  
the HV100 controls the negative supply path.  
Input Voltage  
10V to 72V  
1.4A typ  
Peak Inrush Limit  
Max Short Circuit Current1  
Circuit Breaker Response Time1  
Auto Retry  
4A typ  
Included on board is a 100µF capacitor (C3) to provide a  
capacitive load for testing. Additional capacitance may be  
connected to the VOUT terminals. Or the 100µF may be removed  
altogether  
1ms typ  
2.5s typ  
The board may be modified to meet custom requirements.  
Instructions are provided on the next page for modifications.  
On Resistance  
210mW_ max  
37V on, 34V off  
Undervoltage Trip  
1 During inrush limiting  
Board Layout and Connections  
+OUT  
VPP IN  
V
PP  
OUT  
+
C3  
Power Supply  
or Load  
VIN  
VOUT  
U1  
DRAIN  
GATE  
C2  
C1  
R2  
-OUT  
Q1  
R1  
VIN  
VOUT  
Connect the supply voltage to these terminals. Supply voltage  
may range from 10 volts to 72 volts.  
Connect the power supply or other load to these terminals. VOUT+  
is connected to VIN+, it is VOUT– that is switched.  
A high source impedance may cause oscillations when the input  
voltage is near the undervoltage trip point. A high source  
impedance results in a large voltage drop when loaded, causing  
undervoltage lockout to kick in, disconnecting the load. With the  
load removed, input voltage rises, causing undervoltage to  
release and reconnecting the load. The cycle repeats, resulting  
in oscillations. Source impedance must be less than the follow-  
ing to avoid oscillations:  
Application of a DC load during start-up and/or additional load  
capacitance extends the time inrush limiting is active. If this time  
exceeds 100ms, the HV100 shuts off, retrying 2.5s later. For this  
reason, DC load at start-up should be less than 900mA. Note  
that DC start-up load limitation decreases with added load  
capacitance.  
Note that the circuit breaker functions during inrush only.  
1.5V  
RSOURCE  
=
ILOAD  
01/21/02  
Supertex Inc. does not recommend the use of its products in life support applications and will not knowingly sell its products for use in such applications unless it receives an adequate "products liability  
indemnification insurance agreement." Supertex does not assume responsibility for use of devices described and limits its liability to the replacement of devices determined to be defective due to  
workmanship. No responsibility is assumed for possible omissions or inaccuracies. Circuitry and specifications are subject to change without notice. For the latest product specifications, refer to the  
Supertex website: http://www.supertex.com. For complete liability information on all Supertex products, refer to the most current databook or to the Legal/Disclaimer page on the Supertex website.  

与HV100DB1相关器件

型号 品牌 描述 获取价格 数据表
HV100K5 SUPERTEX 3-Pin Hotswap, Inrush Current Limiter Controllers

获取价格

HV100K5-G SUPERTEX 3-Pin Hotswap, Inrush Current Limiter Controllers (Negative Supply Rail)

获取价格

HV100K6 SUPERTEX 3-Pin Hotswap, Inrush Current Limiter Controllers

获取价格

HV-100V150MH10EQ-R2 TAIYO YUDEN FOR AUTOMOTIVE CONDUCTIVE POLYMER HYBRID ALUMINUM ELECTROLYTIC CAPACITORS[HV]

获取价格

HV100X SUPERTEX 3-Pin Hotswap, Inrush Current Limiter Controllers

获取价格

HV101 SUPERTEX 3-Pin Hotswap, Inrush Current Limiter Controllers

获取价格