REVISION AI
HTS-1XX-X-X-X-X-X
OPTION
NO OF POSITIONS
-01 THRU -36
-N: NON-FLUSH
DO NOT
SCALE FROM
THIS PRINT
(USE SSB-32-U BODY)
(LEAVE BLANK FOR STANDARD)
PLATING SPECIFICATION
-G: 20µ" SELECTIVE GOLD
(USE HTS-36-G)
TERMINAL STYLE
(SEE TABLE 1)
-T: MATTE TIN
(USE HTS-36-L)
(USE HSS-36-L FOR
STYLES -J, -L-X, -M
+.005 [0.13]
.-.008 [0.20]
(NO OF POSITIOINS x .100 [2.54]
.018 0.46 REF
C
.005 0.13 MAX
(N/A ON -N)
"X" MAX
.477 12.12
REF
.100 2.54 REF
.018 0.46 REF
FIG 1
HTS-120-X-AA-1 SHOWN
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
NOTES:
DECIMALS
ANGLES
2
.XX: .01 [.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
C
1.
REPRESENTS A CRITICAL DIMENSION.
.XXX: .005 [.13]
PHONE: 812-944-6733
FAX: 812-948-5047
code 55322
2. MAXIMUM ALLOWABLE BOW: .004[0.10] IN/IN TOP TO BOTTOM
.008[0.20] IN/IN SIDE TO SIDE.
.XXXX: .0020 [.051]
e-Mail info@SAMTEC.com
SHEET SCALE: 2:1
MATERIAL:
DO NOT SCALE DRAWING
DESCRIPTION:
3. MINIMUM PUSHOUT FORCE: 5 LBS.
INSULATOR: LCP,UL 94 V0, COLOR: BLACK
TERMINAL: BRASS, 1/2 HARD
HIGH TEMP, TERMINAL STRIP ASSEMBLY
DWG. NO.
4. MAXIMUM ALLOWABLE TOE IN/OUT OF TERMINALS: 2°.
5. MAXIMUM ALLOWABLE FLASH AFTER REMOVAL OF CROSS BARS: .005[0.13].
6. FOR LEAD STYLES PACKAGED IN TUBES: PACKAGE -05 THRU -36 POSITIONS IN TUBES;
LAYER PACKAGE POSITIONS -01 THRU -04 (SEE TABLE 1).
HTS-1XX-X-X-X-X-X
7. MAXIMUM ALLOWABLE FLASH: .010[0.25].
BY:
L.W.
01/05/1984 SHEET 1 OF 4
F:\DWG\MISC\MKTG\HTS-1XX-X-X-X-X-X-MKT.SLDDRW