Current Transducers HTB 50 .. 400-P
and HTB 50 .. 100-TP
IPN = 50 .. 400 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primarynominal
r.m.s. current
IPN (A)
Primary current
measuring range
IP (A)
Type
50
±150
HTB 50-P, HTB 50-TP1)
100
200
300
400
±300
±500
±600
±600
HTB 100-P, HTB 100-TP1)
HTB 200-P
HTB 300-P
HTB 400-P
Features
· Hall effect measuring principle
· Galvanic isolation between primary
and secondary circuit
· Isolationvoltage2500V
· Low power consumption
· Wide power supply: ±12V to ±15V
· Primary bus bar option for 50A and
100A version for ease of connection
VC
IC
Vd
RIS
VOUT
ROUT
RL
Supplyvoltage(±5%)2)
Currentconsumption
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn
Isolationresistance@500VDC
Output voltage @ ± IPN, RL = 10 kW, TA = 25°C
Outputinternalresistance
±12 .. ±15
<±15
2.5
>500
±4
V
mA
kV
MW
V
100
³ 10
W
kW
Loadresistance
Accuracy - Dynamic performance data
Advantages
X
Accuracy @ IPN, TA = 25°C (without offset)
Linearity (0 .. ± IPN)
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x IPN
<±1
<±1
<±30
% of IPN
% of IPN
mV
e
· Small size and space saving
· Only one design for wide current
ratings range
· High immunity to external
interference.
VOLE
VOH
<±1
<±2.0
% of IPN
mV/K
mV/K
%/K
VOT
Thermal drift of VOE
HTB 50-(T)P
HTB 100-(T)P..400-P <±1.0
TCe
Thermal drift (% of reading)
Response time @ 90% of IP
Frequencybandwidth(-3dB)3)
<±0.1
<3
DC .. 50 kHz
G
tr
f
ms
Applications
· AC variable speed drives
· Static converters for DC motor drives
· Battery supplied applications
· Uninterruptible Power Supplies
(UPS)
· Switched Mode Power Supplies
(SMPS)
· Power supplies for welding
applications.
General data
TA
TS
m
Ambientoperatingtemperature
Ambientstoragetemperature
Mass (-TP version)
2 pins of Ø2mm diameter are available on transducer
for PCB soldering.
-20 .. +80
-25 .. +85
<30 (<36)
°C
°C
g
Notes : EN 50178 approval pending
1) -TP version is equipped with a primary bus bar.
2) Operating at ±12V £ Vc < ±15V will reduce measuring range.
3) Derating is needed to avoid excessive core heating at high frequency.
030529/7