250W Single Output with PFC Function
HSP-250 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 87%
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
1U low profile 41mm
Conformal coated
Built-in cooling fan ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
MODEL
HSP-250-2.5
HSP-250-3.6
HSP-250-5
DC VOLTAGE
2.5V
3.6V
5V
RATED CURRENT
CURRENT RANGE
RATED POWER
50A
50A
50A
0 ~ 50A
125W
0 ~ 50A
0 ~ 50A
250W
100mVp-p
4.5 ~ 5.5V
2.0%
180W
RIPPLE & NOISE (max.) Note.2 100mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
100mVp-p
OUTPUT
2.3 ~ 2.8V
3.24 ~ 3.96V
2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
0.5%
1.0%
0.5%
1.0%
1.0%
3000ms, 50ms/230VAC
3000ms, 50ms/115VAC at full load
16ms/230VAC
Note.5 85 ~ 264VAC
47 ~ 63Hz
16ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
PF>0.95/230VAC
79%
PF>0.98/115VAC at full load
83%
INPUT
87%
1.5A/115VAC
0.75A/230VAC
70A/230VAC
2A/115VAC
1A/230VAC
2.8A/115VAC
1.4A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
35A/115VAC
<1.2mA / 240VAC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
4.14 ~ 4.86V 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
80 (TSW2) detect on heatsink of power transistor ; 80 (TSW1) detect on heatsink of output transistor
OVERLOAD
2.88 ~ 3.38V
PROTECTION OVER VOLTAGE
5
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
RTH3 60 10 Fan on ; RTH3 40 10 Fan off
-40 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
FUNCTION
FAN CONTROL
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A
179.7K hrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
199*105*41mm (L*W*H)
0.97Kg;16pcs/16.5Kg/0.87CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:HSP-250-SPEC 2010-09-27