APPLICABLE STANDARD
-25 C TO
+85 C
-10 C TO
+60 C
OPERATING
STORAGE TEMPERATURE
RANGE
RATING
TEMPERATURE RANGE
VOLTAGE
AC 30 V , DC 42 V
(4)
CURRENT
2 A
APPLICABLE CABLE
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
ELECTRIC CHARACTERISTICS
X
X
15 m MAX.
m MAX.
CONTACT RESISTANCE
CONTACT SHALL BE MEASURED AT DC
CONTACT SHALL BE MEASURED AT DC
100 V DC.
1 A
A
―
―
X
X
1000
M MIN.
INSULATION RESISTANCE
VOLTAGE PROOF
X
X
300 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
WITHDRAWAL FORCES
BY STEEL GAUGE.
INSERTION AND WITHDRAWAL FORCES :
N MIN.
N MAX.
―
―
―
―
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
MEASURED BY APPLICABLE CONNECTOR
LOCKING DEVICE WITH LOCK.
INSERTION AND WITHDRAWAL FORCES : 50
X
X
CONTACT RESISTANCE:
RESISTANCE:
30
m MAX.
m MAX.
MECHANICAL OPERATION
1000 TIMES INSERTIONS AND EXTRACTIONS.
―
―
―
① NO ELECTRICAL DISCONTINUITY OF 10 s.
X
VIBRATION
SHOCK
FREQUENCY 10 TO 55 Hz (1CYC, 5min), SINGLE AMPLITUDE
0.75 mm, AT 10CYC, FOR 3 DIRECTIONS
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
X
X
X
IN OPPOSITE DIRECTIONS OF EACH 3 DEMENSION ALAXIS
FOR 3 TIMES AT 490 m/s2 DURATIONS OF PULSE 11 ms.
APPLYING A PULL FORCE THE WIRE AFTER THE APPLICABLE
CRIMPED CONTACT IS ASSEMBLED THE BODY
―
―
―
CONTACT RETENTION
FORCE
20
N MIN
BREAKING STRENGTH
MAX 30N SHALL BE APPLIED TO CABLE IN UP AND DOWN,
LEFT AND RIGHT DIRECTIONS WHEN MATED
NO BREAKAGE OF CONNECTOR.
ENVIRONMENTAL CHARACTERISTICS
X
X
DAMP HEAT
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
① INSULATION RESISTANCE: 10 MΩ MIN
(AT HIGH HUMIDITY).
―
―
(STEADY STATE)
② INSULATION RESISTANCE:100 MΩ MIN (AT DRY).
③ NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
① INSULATION RESISTANCE: 100 MΩMIN.
② NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
RAPID CHANGE OF TEMPERATURE TEMPERATURE -55→ R/T(1) → +85 → R/T℃
TIME 30 → 10 TO 15 → 30 → 10 TO 15 min
UNDER 5 CYCLES.
EXPOSED IN 5 SALT WATER SPRAY FOR 48 h.
EXPOSED AT + 85 ℃ , 96 h.
X
X
X
X
X
CORROSION SALT MIST
DRY HEAT
NO HEAVY CORROSION.
―
―
―
―
―
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
NO WATER PENETRATION INSIDE CONNECTOR.
NO AIR BUBBLES INSIDE CONNECTOR
EXPOSED AT – 55 ℃ , 96 h.
COLD
(3)
SEALING
EXPOSED AT A DEPTH OF
1m
FOR 0.5 h.
(3)
AIRTIGHTNESS
APPLY AIR PRESSURE 17.6 kPa FOR 0.5min TO INSIDE
CONNECTOR
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
REMARK
APPROVED
CHECKED
DESIGNED
HY.KOBAYASHI
HY.KOBAYASHI
DS.MATSUNE
18.03.16
18.03.16
18.03.16
NOTES(1) R/T:ROOM TEMPERATURE
(2)ABOVE SPECIFICATIONS SHOWS THE VELVE IN ASSEMBLED CONDITION WITH
APPLICABLE CRIMP CONTACT.
(3)SEALING AND AIRTIGHTNESS SHALL BE TESTED BY APPLCIABLE CONNECTOR.
(4)2 A RATE CURRENT IS THE MAXIMUM CURRENT FLOW PER CONTACT.
THE CURRENT CAPACITY OF WHOLE CONNECTOR IS 20.4 A MAX.
DRAWN
DS.MATSUNE
18.03.16
Unless otherwise specified, refer to IEC 60512.(JIS C 5402)
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-112155-31-00
HR30-7R-12PC(31)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL130-1013-8-31
FORM HD0011-2-1