APPLICABLE STANDARD
-25 C TO
+85 C
-10 C TO
+60 C
OPERATING
STORAGE TEMPERATURE
RANGE
RATING
TEMPERATURE RANGE
VOLTAGE
AC 30 V , DC 42 V
2 A
CURRENT
APPLICABLE CABLE
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
ELECTRIC CHARACTERISTICS
X
X
15 m MAX.
m MAX.
CONTACT RESISTANCE
CONTACT SHALL BE MEASURED AT DC
1 A
A
CONTACT SHALL BE MEASURED AT DC
100 V DC.
―
―
X
X
1000
M MIN.
INSULATION RESISTANCE
VOLTAGE PROOF
X
X
300 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
X
X
X
CONTACT INSERTION AND
WITHDRAWAL FORCES
φ0.53±0.003 BY STEEL GAUGE.
INSERTION AND WITHDRAWAL FORCES : 0.4 N MIN.
―
―
―
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
MEASURED BY APPLICABLE CONNECTOR.
INSERTION AND WITHDRAWAL FORCES
LOCKING DEVICE WITH LOCK : 50 N MAX.
CONTACT RESISTANCE:
RESISTANCE:
30
m MAX.
m MAX.
MECHANICAL OPERATION
1000 TIMES INSERTIONS AND EXTRACTIONS.
―
―
―
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
NO BREAKAGE OF CONNECTOR.
X
VIBRATION
FREQUENCY 10 TO 55 Hz(1CYC, 5min), SINGLE AMPLITUDE
0.75 mm, AT 10 CYC, FOR 3 DIRECTIONS
X
X
SHOCK
IN OPPOSITE DIRECTIONS OF EACH 3 DIMENSION ALAXIS
FOR 3 TIMES AT 490 m/s2 DURATION OF PULSE 11 ms.
MAX 30N SHALL BE APPLIED TO CABLE IN UP AND DOWN,
LEFT AND RIGHT DIRECTIONS WHEN MATED
―
―
BREAKING STRENGTH
ENVIRONMENTAL CHARACTERISTICS
X
X
DAMP HEAT
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
① INSULATION RESISTANCE: 10 MΩ MIN
(AT HIGH HUMIDITY).
―
―
(STEADY STATE)
② INSULATION RESISTANCE:100 MΩ MIN (AT DRY).
③ NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
① INSULATION RESISTANCE: 100 MΩMIN.
② NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
RAPID CHANGE OF TEMPERATURE TEMPERATURE -55→ R/T(1) → +85 → R/T℃
TIME 30 → 10 TO 15 → 30 → 10 TO 15 min
UNDER 5 CYCLES.
EXPOSED IN 5 SALT WATER SPRAY FOR 48 h.
EXPOSED AT + 85 ℃ , 96 h.
X
X
X
CORROSION SALT MIST
NO HEAVY CORROSIN RUIN THE FUNCTION.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
NO DEFORMATION OF CASE OF EXCESSIVE LOOSENESS
OF THE TERMINALS.
―
―
―
DRY HEAT
EXPOSED AT – 55 ℃ , 96 h.
COLD
RESISTANCE TO SOLDERING
HEAT
SOLDER TEMPERATURE, + 380 ± 10 ℃ ,FOR IMMERSION
+1
X
X
-
-
DURATION, 3 s.
0
SOLDERABILITY
SOLDERED AT SOLDER TEMPERATURE, + 350 ± 10 ℃ FOR
IMMERSION DURATION, 2 TO 3 s.
WETTING ON SOLDER SURFACE.
NO SOLDER CLUSTER.
(2)
X
X
SEALING
EXPOSED AT A DEPTH OF 1m FOR 0.5 h.
APPLY AIR PRESSURE 17.6 kPa FOR 0.5min TO INSIDE
CONNECTOR
NO WATER PENETRATION INSIDE CONNECTOR.
NO AIR BUBBLES INSIDE CONNECTOR
―
―
(2)
AIRTIGHTNESS
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
REMARK
APPROVED
CHECKED
DESIGNED
HY.KOBAYASHI
HY.KOBAYASHI
DS.MATSUNE
18.03.16
18.03.16
18.03.16
NOTES(1) R/T:ROOM TEMPERATURE
(2)SEALING AND AIRTIGHTNESS SHALL BE TESTED BY APPLCIABLE CONNECTOR.
DRAWN
DS.MATSUNE
18.03.16
Unless otherwise specified, refer to IEC 60512.(JIS C 5402)
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-113486-31-00
HR30-8R-12S(31)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL130-1018-1-31
FORM HD0011-2-1