HPQ-3.3/50-D48 Series
Isolated High Power Quarter Brick DC-DC Converters
www.murata-ps.com
Typical unit
FEATURES
PRODUCT OVERVIEW
Unique among quarter-brick DC-DC converters,
the HPQ-3.3/50-D48 series offers very high output
current (up to 50 Amps) in an industry standard
“quarter brick” package requiring no heat sink. The
HPQ-3.3/50-D48 series delivers up to 165 Watts
shutdown, an external remote On/Off control may
use either positive or negative polarity. Remote
Sense inputs compensate for resistive line drops at
high currents.
3.3 Volts DC fixed output up to 50 Amps
Industry standard quarter brick 2.3" x 1.45" x
0.40" open frame package
Wide range 36 to 75 Vdc input voltages with 2250
Volt Basic isolation
A wealth of self-protection features avoid prob-
fixed voltage output for printed circuit board mount- lems with both the converter and external circuits.
Double lead-free assembly and attachment for RoHS
standards
ing. Wide range inputs on the 2.3" x 1.45" x 0.40"
converter are 36 to 75 Volts DC (48 Volts nominal),
ideal for datacom and telecom systems. The fixed
output voltage is regulated to within 1ꢀ and may
be trimmed within 10ꢀ of nominal output.
Advanced automated surface mount assembly
and planar magnetics deliver full magnetic and
optical isolation with Basic protection up to 2250
Volts. To power digital systems, the outputs offer
fast settling to current steps and tolerance of
higher capacitive loads. Excellent ripple and noise
These include input undervoltage lockout and
overtemperature shutdown using an on-board tem-
perature sensor. Excessive overcurrents limit their
power using the “hiccup” autorestart technique
and the outputs may be short-circuited indefinitely.
Additional safety features include output overvolt-
age protection and reverse conduction elimination.
The synchronous rectifier topology offers high
efficiency for minimal heat buildup and “no heat
sink” operation. The HPQ-3.3/50-D48 series meets
safety certifications to UL/EN/IEC/CSA 60950-1,
Up to 165 Watts total output power
High efficiency synchronous rectifier topology
Stable no-load operation with no required external
components
Operating temperature range -40 to +85° C. with
no heat sink required
Meets UL/EN 60950-1, CSA-C22.2 No. 60950-1,
safety approvals, 2nd Edition
specifications assure compatibility to CPU’s, ASIC’s, 2nd Edition and RFI/EMI conducted/radiated
programmable logic and FPGA’s. No minimum load emission compliance to EN55022-CISPR22 with
is required. For systems needing controlled startup/ external filter.
Extensive self-protection, current limiting and shut
down features
APPLICATIONS
Instrumentation systems, R&D platforms, auto-
Embedded systems, datacom and telecom
installations
mated test fixtures
Disk farms, data centers and cellular repeater sites
Data concentrators, voice forwarding and
speech processing systems
Remote sensor systems, dedicated controllers
+SENSE
(7)
+VIN
(1)
+VOUT
(8)
SWITCH
CONTROL
−VOUT
(4)
–VIN
(3)
−SENSE
(5)
INPUT UNDERVOLTAGE, INPUT
OVERVOLTAGE, AND OUTPUT
OVERVOLTAGE COMPARATORS
PULSE
TRANSFORMER
PWM
CONTROLLER
OPTO
ISOLATION
REFERENCE &
ERROR AMP
VOUT TRIM
(6)
REMOTE
ON/OFF
CONTROL
(2)
Figure 1. Simplified Schematic
Typical topology is shown
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
MDC_HPQ-3.3/50-D48 Series.B01 Page 1 of 11