5秒后页面跳转
HPD65-S480012 PDF预览

HPD65-S480012

更新时间: 2022-12-19 07:42:08
品牌 Logo 应用领域
HITRON 开关输出元件输入元件
页数 文件大小 规格书
2页 280K
描述
UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC INDUSTRIAL DIN-RAIL SINGLE OUTPUT 60 WATTS SWITCHING MODE POWER SUPPLIES

HPD65-S480012 数据手册

 浏览型号HPD65-S480012的Datasheet PDF文件第2页 
H HiTRON  
UNIVERSAL AC INPUT HARMONIC CORRECTION  
AC-DC INDUSTRIAL DIN-RAIL SINGLE OUTPUT 60 WATTS  
SWITCHING MODE POWER SUPPLIES HPD65 SERIES  
FEATURES:  
ACCOMMODATE UNIVERSALAC INPUT  
MEET IEC 61000-3-2 HARMONIC  
CORRECTION  
MEET UNIVERSAL SAFETY STANDARDS  
AND INDUSTRIAL UL 508  
INDUSTRIAL POWER SUPPLIES FOR  
SNAP-ON MOUNTING ON DIN-RAILS  
EMI MEET EN 55022 CLASS B  
CE MARKING COMPLIANCE  
SPECIFICATION  
INPUT SPECIFICATION  
OUTPUT SPECIFICATION  
Output Voltage: See Ratings Charts.  
Output Current: See Ratings Charts.  
Output Wattage: Typ. 60W continuous.  
Output Connector: M-T plug connector.  
Line Regulation: Typ. 0.1%.  
Input Voltage: Typ. 90-264Vac universal AC input.  
Input Connector: M-T plug connector.  
Input Frequency: 47-63Hz.  
Inrush Current: Typ. 15A @ 230Vac.  
Input Current: Typ. 0.7A @ 115Vac/0.38A @ 230Vac.  
Dielectric Withstand: Meet IEC 60950-1.  
EMI: Meet EN 55022/FCC Class B.  
Power Factor Correction: Meet Harmonic Correction  
per IEC 61000-3-2.PF typ.0.93-0.99  
No Load Operation: No damage.  
Load Regulation: Typ. ± 1.0-1.5%  
Noise & Ripple: Typ. 1% peak to peak.  
OVP: Built-in.(Latch).  
Adjustment: Available.  
LED Indicator: Installed.  
Overload Protection (OLP):  
Fully protected against output overload and short circuit.  
Typically set at 135% max. load.  
Consult the factory for special OLP setting.  
Hold-up Time: Typ. 60mS @ 115Vac & 230Vac.  
Earth Leakage: Less than 0.70mA @ 230VAC.  
GENERAL SPECIFICATION  
Efficiency: Typ. 75-78%.  
Operating Temperature: -10 to +70°C.  
Derating from +60 to +70°C by derating 2%/°C.  
Storage Temperature: -25 to +85°C.  
Switching Frequency: Fixed frequency 65.7KHz.  
Circuit Topology: Fixed freq. forward circuit.  
Transient Response: Peak transient about 95mV and  
recovers within 12mS following 25% load change.  
Safety Standard: IEC 60950-1/UL 60950-1 Class I.  
Power Density: 2.76Watts /Cubic Inch.  
Industrial Grade UL 508.  
Temperature Coefficient: Typ. 0.03% /°C.  
Cooling: Free air convection cooling for Ta < +60°C.  
Moving air is request for Ta >+ 60°C full load operation.  
Construction format: Enclosure metal box  
with DIN-clips format.  
Note: Due to requests in market and advances in technology, specifications subject to change without notification.  
In application  