VDE
HP
2c, 3c
10 AMP POWER RELAY
FEATURES
HP RELAYS
25
.984
36
1.417
• Interchangeable with existing models
• Long life and high reliability
• High contact capacity up to 10 A 250 V AC
44.5
1.752
• Available with plug-in/solder and quick-connect terminals
mm inch
SPECIFICATIONS (at 20°C 68°F)
Contacts
Characteristics (at 60 Hz, 20°C 68°F)
Arrangement
2 Form C 3 Form C 4 Form C
15 mΩ
2 Form C 3 Form C 4 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Maximum operating speed
Initial insulation resistance*1
20 cpm
more than 100 MΩ at 500 V DC
Silver
alloy
Between open
contacts
1,000
Vrms
2,000
Vrms
1,000
Vrms
Contact material
Nominal switching
Silver
Breakdown
1,500
Vrms
2,000
Vrms
1,500
Vrms
10 A 250 V AC (resistive)
100 mA, 5 V DC
Between contact sets
capacity
voltage*2
Rating
Min. switching capacity#1
Between contact and
coil
1,500
Vrms
2,000
Vrms
1,500
Vrms
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Max.
25 ms
Operate time*3 (at nominal voltage)
Max. 30 ms
Remarks
Release time (without diode)*3
(at nominal voltage)
Max.
25 ms
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as “initial breakdown voltage” section
*2 Detection current; 10 mA
Max. 30 ms
Max. 65°C
98 m/s2 {10 G}
Temperature rise
*3 Excluding contact bounce time
Functional*4
Destructive*5
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
Shock resistance
980 m/s2 {100 G}
*6 Detection time: 10µs
*7 Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
10 to 55 Hz
at 1 mm double amplitude
Functional*6
Vibration resistance
10 to 55 Hz
at 2 mm double amplitude
Destructive
Conditions for
Ambient
–50°C to +40°C
–58°F to +104°F
operation, transport
temp.
and storage*7
(Not freezing and
condensing at low
temperature)
Humidity
5 to 85% R.H.
Approx.
60g
Approx.
100g
Approx.
125g
Unit weight
2.12 oz
3.53 oz
4.41 oz
LIFE DATA
Contact rating and expected life For AC load type
Voltage
Load
125 V AC
250 V AC
Expected life
(min. operations)
Resistive (cos ϕ ] 1) Inductive (cos ϕ ] 0.4) Resistive (cos ϕ ] 1) Inductive (cos ϕ ] 0.4)
—
10 A
5 A
1A
—
7.5 A
10 A
7.5 A
3 A
7.5 A
5 A
2×105
5×105
1×106
2×106
1×107
Electrical
life
Current
3 A
2 A
0.7 A
0.6 A
0.4 A
Mechanical life
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.