Absolute Maximum Ratings
T = 25°C
J
Parameter
Red
Green and Blue
30
100 [3]
Unit
mA
mA
mW
V
DC Forward Current [1]
Peak Forward Current
Power Dissipation
50
100 [2]
120
116
Reverse Voltage
5 (IR = 100 μA)
130
5 (IR = 10 μA)
110
LED Junction Temperature
Operating Temperature Range
Storage Temperature Range
°C
-40 to +100
-40 to +100
-40 to +85
-40 to +100
°C
°C
Notes:
1. Derate linearly as shown in Figure 4.
2. Duty Factor 30ꢀ, frequency 1KHz.
3. Duty Factor 10ꢀ, frequency 1KHz.
Electrical / Optical Characteristics
T = 25°C
J
Parameter
Symbol
Min.
Typ.
Max.
Units
Test Conditions
Forward Voltage
VF
V
IF = 20 mA
Red
Green
Blue
1.8
2.8
2.8
2.1
3.2
3.2
2.4
3.8
3.8
Reverse Voltage
Red
VR
V
5
5
IF = 100 μA
IF = 10 μA
Green & blue
Dominant Wavelength [1]
nm
IF = 20 mA
Red
Green
Blue
λd
618
520
460
626
525
470
630
540
480
Peak Wavelength
Red
Green
Blue
λPEAK
634
516
464
nm
Peak of Wavelength of Spectral
Distribution at IF = 20 mA
Thermal Resistance
Luminous Efficacy [2]
RθJ-PIN
240
°C/W
lm/W
LED Junction-to-Pin
Red
Green
Blue
ηV
150
530
65
Emitted Luminous Power/Emitted
Radiant Power
Notes:
1. The dominant wavelength is derived from the chromaticity Diagram and represents the color of the lamp
2. The radiant intensity, Ie in watts per steradian, may be found from the equation Ie = I /η where I is the luminous intensity in candelas and η is
V
V
V
V
the luminous efficacy in lumens/watt.
3