6
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause catastrophic damage to the device. Limits apply to each parameter in isolation,
all other parameters having values within the recommended operating conditions. It should not be assumed that limiting values of more than one
parameter can be applied to the product at the same time. Exposure to the absolute maximum ratings for extended periods can adversely affect
device reliability.
Parameter
Storage Temperature
Symbol
TS
Min.
-40
Typ.
Max.
+100
7.0
Unit
°C
V
Reference
Supply Voltage
VCC
VI
-0.5
-0.5
1
2
Data Input Voltage
VCC
1.6
V
Transmitter Differential Input Voltage
Output Current
VD
V
ID
50
mA
ꢀ
Relative Humidity
RH
5
95
Recommended Operating Conditions
Parameter
Ambient Operating Temperature
Case Temperature
Symbol
Min.
Typ.
Max.
+70
Unit
°C
°C
V
Reference
TA
TC
0
3
4
+90
Supply Voltage
VCC
4.75
5.25
Power Supply Rejection
PSR
VIL-VCC
VIH-VCC
VD
50
mVP-P
V
5
6
6
Transmitter Data Input Voltage - Low
Transmitter Data Input Voltage - High
Transmitter Differential Input Voltage
Data Output Load
-1.810
-1.165
0.3
-1.475
-0.880
1.6
V
V
RDL
50
7
7
Signal Detect Output Load
RSDL
50
Process Compatibility
Parameter
Symbol
Min.
Typ.
Max.
Unit
Reference
Hand Lead Soldering Temperature/Time
Wave Soldering and Aqueous Wash
T
SOLD/tSOLD
+260/10 °C/sec.
+260/10 °C/sec.
T
SOLD/tSOLD
8
Notes:
1. The transceiver is class 1 eye safe up to V = 7 V.
CC
2. This is the maximum voltage that can be applied across the Differential Transmitter Data Inputs without damaging the input
circuit.
3. 2 m/s air flow required.
4. Case temperature measurement referenced to the center-top of the internal metal transmitter shield.
5. Tested with a 50 mV
sinusoidal signal in the frequency range from 500 Hz to 1500 kHz on the V supply with the
CC
P-P
recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced.
6. Compatible with 10 K, 10 KH, and 100 K ECL and PECL input signals.
7. The outputs are terminated to V -2 V.
CC