18
HFBR-25X3 Receiver
Pin #
Function
DO NOT CONNECT
5
1
2
3
4
5
8
V
O
V
CC
4
3
Ground
Open
OPEN
GROUND
2
1
V
CC
V
O
Do not connect
Do not connect
DO NOT CONNECT
8
Note: Pins 5 and 8 are for mounting and
retaining purposes only. Do not
electrically connect these pins.
Absolute Maximum Ratings
Parameter
Symbol
Min.
–40
–40
Max.
+85
+85
260
10
7
5
25
7
Units
°C
°C
°C
sec
V
mA
mW
V
Reference
Storage Temperature
Operating Temperature
T
S
T
A
Lead Soldering Cycle
Temp.
Time
Note 1
Note 2
Supply Voltage
V
–0.5
–1
CC
Average Output Collector Current
Output Collector Power Dissipation
Output Voltage
I
O
P
OD
V
O
–0.5
Notes:
1. 1.6 mm below seating plane.
2. It is essential that a bypass capacitor 0.01 µF be connected from pin 2 to pin 3 of the receiver.
Receiver Electrical/Optical Characteristics 0°C to 70°C, 4.5 V ≤ VCC ≤ 5.5 V unless otherwise
specified.
Parameter
Input Optical Power
Level Logic 0
Symbol Min. Typ. Max. Units
Conditions
Ref.
PR(L)
–39
–39
–13.7 dBm VO = VOL, IOL = 3.2 mA Notes 1,
2, 3
–13.3
–53
VO = VOL,
IOH = 8 mA, 25°C
Input Optical Power
Level Logic 1
High Level Output Voltage
Low Level Output Voltage
PR(H)
VOH
dBm VOH = 5.5 V
Note 3
IOH = ≤ 40 µA
IO = -40 µA, PR = 0 µW
IOL = 3.2 mA
PR = PR(L)MIN
VCC = 5.5 V, PR = 0 µW
2.4
V
V
V
OL
0.4
Note 4
Note 4
High Level Supply Current
Low Level Supply Current
ICCH
ICCL
1.2
2.9
1.9
3.7
mA
mA
VCC = 5.5 V,
PR = PRL (MIN)
Effective Diameter
Numerical Aperture
D
NA
1
0.5
mm
Notes:
1. Measured at the end of the fiber optic cable with large area detector.
2. Optical flux, P (dBm) = 10 Log P(µW)/1000 µW.
3. Because of the very high sensitivity of the HFBR-25X3, the digital output may switch in response to ambient light levels when a
cable is not occupying the receiver optical port. The designer should take care to filter out signals from this source if they pose a
hazard to the system.
4. Including current in 3.3 k pull-up resistor.