NON-CONDUCTIVE
PLASTIC HOUSING
DATE CODE
PART NUMBER
METAL PORT
1
2
3
4
5
6
7
8
Port Ground Pin
Part Dependent
Part Dependent
Port Ground Pin
Port Ground Pin
Part Dependent
Part Dependent
Port Ground Pin
PINS 1,4,5,8
0.51 X 0.38
(0.020 X 0.015)
PINS 2,3,6,7
0.46 DIA
(0.018) DIA
PIN NO. 1
INDICATOR
This option will be available with
the following part numbers:
Low Cost Miniature Link
Components with the Metal Port
Option use the same semi-
conductor devices and
manufacturing processes as
standard HFBR-0400
components, so reliability data
for the HFBR-0400 Series is
directly applicable. The tests
listed below demonstrate the
mechanical reliability of this
package.
Refer to the HFBR-14XX and
HFBR-24XX data sheeets for
electrical/optical/mechanical
specifications for each part. To
order the Metal Port Option with
a particular transmitter or
receiver component, simply add
the letter “M” to the end of the
standard part number. For
example, HFBR-1412T with
the metal port option is
HFBR-1402
HFBR-1412
HFBR-1412T
HFBR-1422
HFBR-1404
HFBR-1414
HFBR-1414T
HFBR-1424
HFBR-2402
HFBR-2412
HFBR-2412T
HFBR-2422
HFBR-2406
HFBR-2416
HFBR-2416T
HFBR-2426
HFBR-1412TM.
Temperature Cycling
1010
Condition B
-55 to +125°C, 15 minutes dwell,
5 minutes transfer, 170 cycles
121°C, 100% relative humidity,
2 atmospheres, 48 hours
5 blows each X1, X2, Y1, Y2, Z1, Z2
1500 G, 0.5 msec. pulse
50 G, 20 to 2000 Hz. 4,
40
5
0
0
0
0
Unbiased Pressure
Pot Test
Mechanical Shock
2002
Condition B
2007
Condition A
40
40
Vibration Variable
Frequency
4 minute cycles each X, Y, Z
76