(888) IPD-CONVerters
ꢀ
(888) 473-2668
ꢀ
www.ipdconverters.com
HES SERIES - 150 WATT
DESCRIPTION
FEATURES
HES single output DC/DC converters provide up to
150 Watts of output power in an industry standard,
half-brick package and footprint. These units feature
ultra-high efficiency, Class A conducted noise specs, and
fixed switching frequency. The HES is designed with
open-frame packaging, along with planar magnetics to
provide maximum useable power with minimal thermal
constraints. The HES is especially suited to harsh
telecom, networking, and industrial applications, and is
fully compatible with production board washing
processes.
• High Efficiency
• Industry Standard Half-
Brick
• Open-Frame Packaging
• 100°C Baseplate Operation
• Water Washable
• “True-Trim” Option
• 1500V Isolation
• Positive or Negative
Logic
Efficiency vs. Load (48V Input)
95
90
85
80
75
70
65
60
55
50
HES033ZE
HES075ZG
HES100ZE
1
2
3
4
5
6
7
8
9
10
X10 = LOAD %
General
Turn-On Time
Remote Shutdown
10 ms
Positive Or Negative Logic
Remote Shutdown Reference
Vin Negative
Switching Frequency 2.5 & 3.3, 5V Model
Isolation
Input - Output
Input - Case
200 kHz, 300 kHz (Respectively)
1500 VDC
1050 VDC
500 VDC
0.2%/°C
TECHNICAL SPECIFICATIONS
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
-40 To +100°C
-40 To +125°C
105 To 115°C
18 - 36 VDC
36 - 72 VDC
50 mA
Storage Range
Thermal Shutdown Range
Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
MTBF (Bellcore Tr-nwt-000332)
1.8 X 106 hrs
†
Input Reverse Voltage Protection
Input Undervoltage Lockout / Hysteresis
Shunt Diode
<34V/1V Nom.
Safety
Weight (Approx.)
UL 1950, Csa 22.2-950, En60950
1.4 oz
Output
Notes
Industrial temp range of -40 to +85C available, add suffix -I to P/N
MTBF predictions may vary slightly from model to model.
Setpoint Accuracy
±1%
1
†
Line Regulation Vin Min. - Vin Max., Iout Rated
0.2% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom.
0.2% Vout
Remote Sense Headroom
Minimum Output Current
0.5 VDC
10 %
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Dynamic Regulation, Loadstep
25% Iout
Pk Deviation
Settling Time
4% Vout
500 µs
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Voltage Trim Range
Short Circuit / Overcurrent Protection
±10%
Shutdown / Hiccup
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Current Limit Threshold Range, % of Iout Rated
110 - 130%
OVP Trip Range
OVP Type
120 - 140% Vout Nom.
Self Recovering
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.