更新时间: 2022-02-26 09:41:23
品牌 Logo 应用领域
HITRON /
页数 文件大小 规格书
2页 239K
描述
Energy Efficiency Level VI

HEMG56-S480110-8 数据手册

 浏览型号HEMG56-S480110-8的Datasheet PDF文件第2页 
H HiTRON  
Universal input AC-DC Medical and ITE application external desktop  
switching adapter 50 Watts green power single output HEMG56 series  
Features  
Energy Efficiency Level VI  
Accommodate universal AC input  
Medical & ITE Application  
Wide operating temperature range and  
high efficiency  
Class I and Class II construction  
CE marking compliance  
Specification  
Input  
Protection  
Input Voltage  
Input Frequency  
Input Current  
90-264VAC  
Over Load  
Typical set at about 120% of  
rating output wattage  
47-63Hz  
Typical 0.72A at 115VAC  
Typical 0.43A at 230VAC  
13.4Arms (72Apk) at 230VAC  
3 pole IEC320-C14 (DT7)  
2 pole IEC320-C8 (DT8)  
Less than 0.18 mA  
Less than 0.16W  
General  
Efficiency  
Typical 80-92% (depending on model)  
65KHz  
Inrush Current  
Switching Frequency  
Dielectric Withstand  
Circuit Topology  
Transient Response  
Input Connector  
IEC60601-1 and IEC60950-1  
Fixed Frequency Flyback  
Output voltage returns in less than  
1mS following a 25% load change  
2.8-4W / Cubic inch  
Earth Leakage Current  
No Load Power  
Output  
Power Density  
Output Connector/Plug  
Line Regulation  
Load Regulation  
Total Regulation  
Noise & Ripple  
Adjustability  
Optional  
Environmental  
Operating Temperature  
Storage Temperature  
Cooling  
Typical 0.1%  
-25°C to +40°C  
Typical ±3%  
-40°C to +85°C  
Typical ±2%  
Convection-cooled  
10-95% RH, non-condensing  
5-95% RH  
Typical 1% peak to peak  
Factory set  
Operating Humidity  
Storage Humidity  
Hold-up Time  
Typical 20mS at 115VAC  
Typical 81mS at 230VAC  
Safety/EMC  
Emissions  
EN55011 & EN55032 FCC Class B  
IEC60601-1 Class I and Class II  
IEC60950-1 Class I and Class II  
Safety Standard  
Protection  
Over Voltage  
Built-in  
Built-in  
Over Current  
Notes:  
(1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.  
(2) Load regulation is measured at 115VAC or 230VAC in percentage to indicate the change in output voltage as the load varied from half load to full load ( %).  
(3) The exact obtainable load regulation depends upon the output cord selected and load current.  
(4) HEMG56 can meet Energy Efficiency Level VI and CEC except 5V output.  
(5) Due to requests in market and advances in technology, specifications subject to change without notice  

与HEMG56-S480110-8相关器件

型号 品牌 描述 获取价格 数据表
HEMG75 HITRON AC/DC MEDICAL APPLICATION EXTERNAL ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 70 WATTS GREEN PO

获取价格

HEMG75-120530-7 HITRON AC/DC MEDICAL APPLICATION EXTERNAL ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 70 WATTS GREEN PO

获取价格

HEMG75-150470-7 HITRON AC/DC MEDICAL APPLICATION EXTERNAL ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 70 WATTS GREEN PO

获取价格

HEMG75-180400-7 HITRON AC/DC MEDICAL APPLICATION EXTERNAL ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 70 WATTS GREEN PO

获取价格

HEMG75-240280-7 HITRON AC/DC MEDICAL APPLICATION EXTERNAL ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 70 WATTS GREEN PO

获取价格

HEMG75-300240-7 HITRON AC/DC MEDICAL APPLICATION EXTERNAL ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 70 WATTS GREEN PO

获取价格