HDC3020
SNAS778 – JUNE 2021
www.ti.com
HDC3x
DEF, DEH, and DEJ
8 PINS
THERMAL METRIC(1)
UNIT
ΨJB
Junction-to-board characterization parameter
Junction-to-case (bottom) thermal resistance
51.7
°C/W
°C/W
RθJC(bot)
30.4
(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report.
(2) JEDEC standard JESD51-X specifies this measurement at the center position on the top surface of the package. Due to the location of
the cavity opening at the center position, this measurement is not applicable.
6.5 Electrical Characteristics
TA = -40°C to 125°C, VDD = 1.62V to 5.50V (unless otherwise noted), Typical Specifications are TA = 25°C, VDD
=
1.8V unless otherwise noted
PARAMETER
Current Consumption
TEST CONDITIONS
MIN
TYP
MAX
UNIT
Low Power Mode 0 (lowest noise)
Low Power Mode 1
125
TBD
TBD
100
TBD
IDD_ACTIVE Active Current(1)
µA
Low Power Mode 2
Low Power Mode 3
TBD
TBD
No Active Measurement
trigger on demand mode
0.4
IDD_SLEEP Sleep Current(1)
µA
No Active Measurement,
auto measurement mode
0.55
TBD
IDD_AVG_E
measurement freq = numbers of samples per
second
(9)
Averaged Current Equation
QN
Low Power Mode 0 (lowest noise)
Averaged at 1 sample per second
2.0
1.2
1.0
0.9
0.7
30
TBD
TBD
TBD
TBD
TBD
TBD
Low Power Mode 1
Averaged at 1 sample per second
Low Power Mode 2
Averaged at 1 sample per second
IDD_AVG
Averaged Current(1) (2)
µA
Low Power Mode 3 (lowest power)
Averaged at 1 sample per second
Low Power Mode 3 (lowest power)
Averaged at 1 sample every two seconds
Heater Current (Condensation
Removal)
THEATER - TAMBIENT = 20°C. VDD = 3.3V for
Typical Value
IHEATER
mA
Sensor Timing
Low Power Mode 0 (lowest noise)
Low Power Mode 1
12.0
7.0
4.5
3.3
TBD
TBD
TBD
TBD
tmeas
Measurement Duration (8)
ms
ms
ms
Low Power Mode 2
Low Power Mode 3 (lowest power)
Sensor ready once VDD ≥ 1.62V
TA = 25°C
0.5
1
SensorPU
Power Up Ready
Soft Reset Ready
R
Sensor ready once VDD ≥ 1.62V
1.5
Sensor ready once Soft Rest Command
received
TA = 25°C
0.5
1
SensorSR
R
Sensor ready once Soft Rest Command
received
1.5
Relative Humidity Sensor
RHACC
Accuracy(3) (4)
TA = 25°C, 10% to 90% RH
±1.5
±2
%RH
Copyright © 2021 Texas Instruments Incorporated
Submit Document Feedback
5
Product Folder Links: HDC3020