90W AC-DC Single Output Desktop
GS90 series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Built-in active PFC function, PF>0.91
Protections: Short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / TUV / BSMI / CB / FCC / CE
Class power ( with earth pin)
Pass LPS
LED indicator for power on
No load power consumption<0.5W
Meet EISA 2007(Energy Independence and Security Act)
2 years warranty
TUV
Rheinland
geprUfre
Sicherheit
Product Safety
(except for 48V)
SPECIFICATION
ORDER NO.
GS90A12-P1M
GS90A15-P1M
GS90A19-P1M
GS90A24-P1M
GS90A48-P1M
SAFETY MODEL NO.
GS90A12
GS90A15
15V
GS90A19
19V
GS90A24
24V
GS90A48
48V
DC VOLTAGE
Note.2 12V
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
6.67A
6A
4.74A
3.75A
1.87A
0 ~ 6.67A
80W
0 ~ 6A
90W
0 ~ 4.74A
90W
0 ~ 3.75A
90W
0 ~ 1.87A
90W
OUTPUT
RIPPLE & NOISE (max.) Note.3 80mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
100mVp-p
5.0%
150mVp-p
4.0%
180mVp-p
3.0%
240mVp-p
2.0%
LINE REGULATION
Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
LOAD REGULATION
SETUP, RISE TIME
Note.6 5.0%
5.0%
4.0%
3.0%
2.0%
Note.8 1000ms, 20ms / 230VAC
1000ms, 20ms / 115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
20ms / 230VAC
Note.9 90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
20ms / 115VAC at full load
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
PF>0.91 / 230VAC
88%
PF>0.95 / 115VAC at full load
INPUT
89%
89%
89.5%
91%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
2A / 115VAC
70A / 230VAC
1mA / 240VAC
1A / 230VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
RTH30 > 100
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03% / (0~50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, J60950-1(except for 48V) approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P: 3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC EMISSION
EMC
(Note. 7)
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
EMC IMMUNITY
MTBF
348.7Khrs min. MIL-HDBK-217F(25
145*60*32mm (L*W*H)
)
DIMENSION
OTHERS
0.45Kg; 30pcs/14.05Kg/1CUFT
PACKING
PLUG
Standard type P1M: 2.5 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
CONNECTOR
CABLE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
NOTE
5. Line regulation is measured from low line to high line at rated load.
6. Load regulation is measured from 10% to 100% rated load
7. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
8. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
File Name:GS90-SPEC 2011-06-15