GenesysTM 3U 10kW Specifications
10kW
1.0 MODEL
GEN
VDC
ADC
kW
150-66 200-50 250-40 300-33 400-25 500-20 600-17 800-12.5 1000-10 1250-8
1500-6.7
1500
6.7
X
X
X
X
X
X
1.Rated Output Voltage
2.Rated Output Current
150
66
200
50
250
40
10.0
300
33
9.9
83
400
25
10.0
500
20
10.0
600
17
10.2
800
12.5
10.0
1000
10
10.0
1250
8.0
10.0
3.Rated Output Power
9.9
10.0
10.0
4.Efficiency (min) at low AC line, 100% Rated Load
%
93.5
Contact Factory for other models
1.1 CONSTANT VOLTAGE MODE (CV)
1. Max. Line Reg (0.1% - Vor ≤ 30V; 0.05% - 30V < Vor <
600V; 0.05% - 600V < Vor < 1500V)
2. Max. Load Reg (0.1% - Vor ≤ 30V; 0.05% - 30V < Vor <
600V; 0.1% - 600V < Vor < 1500V)
mV
mV
75
75
100
100
125
125
150
150
200
200
250
250
300
300
400
800
500
625
750
X
X
1000
1250
1500
3. Output Ripple, rms (5Hz~1MHz), CV mode; (*1)
4. Output Noise, p-p (20MHz), CV mode; (*1)
5.Remote Sense Compensation / Wire
6. Temperature Stability
mV
mV
V
25
150
5
35
175
5
35
200
5
60
200
5
60
300
5
60
350
5
60
350
5
80
700
5
100
800
5
120
1000
5
140
1400
5
X
X
X
X
X
X
X
X
---
± 0.05% of Vo(rated) over 8 hours after 30 minute warm up (constant Line, Load & Temperature)
7. Temperature Coefficient
ppm / °C ± 200 (0.02% of Vo(rated)) / °C
8. Up-Prog. Response Time, 0~Vomax, full-load
9. Up-Prog. Response Time, 0~Vomax, no load
10. Transient Response Time (CV mode); (*2), (*3)
ms
ms
ms
100
50
Less than 3
17
17
Less than 1
1.2 CONSTANT CURRENT MODE (CC)
1. Max. Line Reg. (0.1% - Ior > 333A; 0.050% - 17A < Ior <
mA
mA
33
25
20
17
13
10
9
19
15
12
10
X
X
333A; 0.15% - Ior < 17A)
2. Max. Load Reg (0.1% - Ior > 333A; 0.075% - 17A < Ior <
333A; 0.2% - Ior < 17A)
3. Output Ripple, rms (5Hz~1MHz), CC mode
4. Temperature Stability
5. Temperature Coefficient
50
26
38
20
30
16
25
13
19
10
15
8
13
7
25
15
20
10
15
6
14
4
mA
---
X
X
X
± 0.05% of Io Rated over 8 hours after 30 minute warm up (constant Line, Load & Temperature)
ppm / °C ± 300 (0.03% of Io(rated)) / °C
1.3 PROTECTIVE FUNCTIONS
1. OCP
2. OCP type
3. Foldback Protection (FOLD)
4. Foldback Response Time
5. OVP type
%
---
---
s
---
%
0 ~ 100
Constant current
X
X
X
X
X
X
Output shut down; Manual reset by front panel OUT button or Digital communication, user-selectable
Less than 1 (Min = 0.25 / Max = 25 / Default = 0.25); Settable via “FBD” command
Inverter shut-down; Manual reset by AC On/Off recycle, OUT button, Remote Analog or Digital comm.
± 5% of Vo(rated)
6. OVP Programming Accuracy
5% to 105% of Vo(rated) - for Vor < 600V; 10% to 105% of Vo(rated) - 600V < Vor < 1500V
Shall always be greater than 105% of Vo(setting); Default = 105% of Vo(rated)
Less than 10 (for Output to begin to drop) for Vor < 600V
7. OVP Trip Point
V
X
X
8. OVP response time
ms
Less than 2.0 (for Output to begin to drop) for 600V < Vor < 1500V
7 (from AC On/Off switch turn On)
9. Max. OVP reset time
10. Over-Temperature Protection (OTP)
11. Phase-Loss Protection
s
---
---
X
X
X
Shut down if internal temperature exceeds safe operating levels. (Latched: Safe / Unlatched: Auto)
Yes, power supply shutdown (Latched: Safe-Start / Unlatched: Auto-Restart)
1.4 REMOTE ANALOG CONTROLS & SIGNALS
1. Vout Voltage Programming
2. Iout Voltage Programming
3. Vout resistor programming
4. Iout Resistor Programming
5. Shut-Off (SO) Control (rear panel)
6. Output Current Monitor
7. Output Voltage Monitor
8. Power Supply OK (PS_OK) Signal
9. CV/CC Signal
0~100%, 0 ~ 5V or 0 ~ 10V, user-selectable, Accuracy & Linearity: ± 1% of Vo(rated)
0 ~ 100%, 0~5V or 0 ~ 10V, user-selectable. Accuracy & Linearity ± 1% of Io(rated)
0~100%, 0~5/10kohm full-scale, user-selectable. Accuracy & Linearity ± 1% of Vo(rated)
0~100%, 0~5/10kohm full-scale, user-selectable. Accuracy & Linearity ± 1% of Io(rated)
By Voltage: 0.6V = DIS, 2-15V = ENA (default) or Dry Contact : Open = ENA, Short = DIS (user-selectable logic)
0 ~ 5V or 0 ~ 10V, Accuracy: ± 1% of Io(rated), user-selectable
0 ~ 5V or 0 ~ 10V, Accuracy: ± 1% of Vo(rated), user-selectable
Yes. TTL high = OK, 0V = Fail (500ohm series impedance)
CV: TTL High (4 ~ 5V), Max source current = 10mA; CC: TTL Low (0 ~ 0.4V), Max sink current = 10mA
Dry contact; Open = OFF, Short = ON; Maximum voltage across Enable/Disable contacts = 6V
Selects Remote or Local operation by voltage: 0 ~ 0.6V = Local / 2 ~ 15V = Remote
Signals operating mode; Open collector: Local = Open (Max voltage = 30V), Remote = On (Max sink current = 10mA)
X
X
X
X
X
X
X
X
X
X
X
X
10. Enable/Disable
11. Remote/Local Selection
12. Remote/Local Signal
1.5 FRONT PANEL
1.Control Functions
X
X
X
X
X
X
X
X
X
X
Vout/ Iout manual adjust by separate encoders (COARSE and FINE adjustment selectable)
OVP/UVL manual adjust by VOLTAGE Adjust encoder, Front Panel Lock/Unlock
Address selection by Voltage Adjust encoder. # of Addresses = 31
AC ON/OFF, Output On/Off, Restart Modes (Auto/Safe), Foldback Control (CV to CC), Go-to-Local
RS-232/RS-485, LAN, IEEE (IEMD) and USB selection by rear-panel DIP-switch
Baud rate selection (RS-232/RS-485 only): 1200, 2400, 4800, 9600 and 19,200 (by CURRENT Adjust encoder)
Advanced Parallel Master/Slave: Hx = Master unit, where x = # of Slave units (0 to 4), Slave = Slave unit(s)
Voltage: 4 digits, Accuracy: ± 0.5% of Vo(rated) ±1 count
2.Display
Current: 4 digits, Accuracy: ± 0.5% of Io(rated) ±1 count
VOLTAGE meter displays voltage at power supply (Local sense) or at load (Remote sense)
3.Indications
Green LED’s: PREVIEW, FOLD, REM/LOCAL, OUT ON/OFF, CV/CC, FINE
Red LED: ALARM (OVP, OTP, FOLD, AC FAIL, ENA, SO)
X
1.6 DIGITAL PROGRAMMING & READBACK
1. Vout Programming Accuracy
2. Iout Programming Accuracy
3. Vout Programming Resolution
4. Iout Programming Resolution
5. Vout Readback Accuracy
6. Iout Readback Accuracy
7. Vout Readback Resolution
8. Iout Readback Resolution
9. OV Response Time
± 0.5% of Vo(rated)
X
X
X
X
X
X
X
X
X
X
± 0.5% of Io(rated) for units with Io < 187.5A; ± 0.7% of Io(rated) for Io ≥187.5A
0.02% of Vo(rated)
0.04% of Io(rated)
± (0.1% of Vo(actual) + 0.2% of Vo(rated))
± (0.1% of Io(actual) + 0.4% of Io(rated))
0.02% of Vo(rated)
0.02% of Io(rated)
20ms maximum (between Vout exceeding IEEE Limit and supply Inhibit turning On)
Set OVP/UVL limits; Set Local/Remote, Operating Parameters and Status; Get Identity
10. Other Functions
*1. Ripple and Noise at Vo(rated) and rated Load, Ta = +25C and nominal AC input, per EIJ R9002A
*2. Time for the Output voltage to recover within 2% of rating for a load current change of 50~100% or 100~50% of Io(rated).
*3. Operating with a load that continuously pulses the current (or voltage) can reduce the operating life of the Power Supply. Please contact TDK-Lambda Sales/Technical Support to discuss
the application in detail.
All specifications subject to change without notice.