AC-DC Power Supplies
GCS265 Series
Signals & Controls
Characteristic
Notes & Conditions
Open collector pin 6 referenced to -ve sense pin 2 of J4.
Provides ≥2 ms warning of loss of output from AC failure.
Power Fail (AC-OK)
Standby Supply
Remote Sense
5 VDC/3.0 A Isolated supply present when AC applied.
Compensates for 0.5 V total voltage drop
The inhibit lo (pin 4), should be pulled below 0.4 V to switch V1 & Vfan off. Open circuit or >4 V to
switch on (see fig. 7)
Inhibit
Remote On/Off
With the inhibit lo (pin 4) pulled low as detailed above, connecting inhibit hi (pin 5) to inhibit lo (pin 4)
will enable V1 & V fan output. (see fig. 8)
Enable
Power Fail (AC-OK)
Remote On/Off (Inhibit)
Remote On/Off (Enable)
Figure 6
Figure 7
Figure 8
POWER SUPPLY
5 V Standby
POWER SUPPLY
POWER SUPPLY
Inhibit Hi
Pin 5
Pin 7 & 8
330R
Max 12 V 20 mA
Inhibit Lo
Pin 4
Inhibit Lo
Pin 4
AC OK Collector
Pin 6
Transistor On (<0.8 V): AC NOT OK
Transistor Off (>4.5 V): AC OK
AC OK Emitter
Pin 2
0 V
0 V
J4 Logic Connector
5 V Standby
Return Pin 9 & 10
Signals Connector
Signals Connector
Environmental
Characteristic
Minimum
Typical
Maximum
Units
°C
Notes & Conditions
Operating Temperature
Storage Temperature
Cooling
-40
-40
7
+70
+85
See derating curve, fig. 9
°C
CFM
%RH
m
Forced Cooled >180 W
Non-condensing
Humidity
5
95
Operating Altitude
TBA
3 x 30g shocks in each plane, total 18 shocks. 30g =
11ms (+/-0.5msec), half sine. Conforms to EN60068-2-27
& EN60068-2-47
Shock
Single axis 10 - 500 Hz at 2g sweep and endurance at
resonance in all 3 planes. Conforms to EN60068-2-6
Vibration
Thermal Derating Curve
Figure 9
100
50
0
-40
-20
0
+50
+70
Ambient Temperature (ºC)
www.xppower.com
4