50-60W
OPEN-FRAME SWITCHING POWER SUPPLIES
FLU1-50 AND MDU1-50 SERIES
A. Dimensions shown are in inches.
B. Tolerances = 0.00 0.01 inch.
0.000 0.005 inch.
C. P1 input connectors are Molex 26-60-4030. The mating connector
combines Molex housing 43061-0003 and crimp terminal 08-70-1030.
D. P2 output connectors are Molex 26-60-4060. The mating connector
combines Molex housing 43061-0006 and crimp terminal 08-70-1030.
Pin-Out
Pin
FLU1-50
MDU1-50
1
2
3
4
5
6
V1
V1
V1
Return
Return
Return
V1
V1
V1
Return
Return
Return
DC50 SERIES
A. Dimensions shown are in inches.
B. Tolerances = 0.00 0.01 inch.
0.000 0.005 inch.
C. P1 input connectors are Molex 26-60-4080. The mating
connector combines Molex housing 09-50-8081 and
crimp terminal 03-50-0106.
D. P2 output connectors are Molex 26-60-4100. The mat-
ing connector combines Molex housing 09-50-8101 and
crimp terminal 03-50-0106.
E. Under-voltage shutdown on the DC50 series is activated
at 10% below low line, typical. Over-voltage shutdown is
typically activated at 10% above high line.
F. A TTL HIGH signal at the external shutdown pin of the
DC50 series disables the unit.
G. External frequency synchronization of the DC50 series
requires a 2.8V positive pulse (>9.1 µs) at the external
synch pin.
Pin-Out
Pin
DC50
1
2
3
V3
V3 Return
V2
4
V2
5
6
7
V2 Return
V2 Return
V1
8
V1
9
10
V1 Return
V1 Return