Sampling IF Receiver 600MHz to
1000MHz
F0502
Datasheet
TYPICAL OPERATING CONDITIONS (184 MHZ IF CENTER)
Unless otherwise noted, the following conditions apply:
•
Applications circuit for 100 differential load with 184MHz +/- 40MHz BW into 2:1 transformer. See
schematic in BOM section.
•
•
•
•
•
•
•
•
•
•
•
Pout ~ +3dBm
Measurement on Channel A
PIN from -27dBm to -5dBm per tone (Gain Setting Adjusted to yield Pout ~ +3dBm)
Tone Spacing = 800KHz
Device configured in Standard Mode with High Side Injection
TCASE = 25C, VCC = 5.00V, LO Power = 0dBm
RF Frequency: 915MHz
IF Frequency: 184MHz
IF Transformer losses are de-embedded
Input RF trace and connector losses are de-embedded
Listed Temperatures are Case Temperature (TC = Case Temperature)
•
Where noted, TA or TAMB = Ambient Temperature
FlatNoiseTM, Zero-DistortionTM, SIF Rx
9
February 8, 2022