F0240YH300 PDF预览

F0240YH300

更新时间: 2023-12-06 20:13:13
品牌 Logo 应用领域
力特 - LITTELFUSE 开关
页数 文件大小 规格书
12页 653K
描述
此系列产品可提供最低的反向恢复电流实际值,同时提供现代开关器件所需的宽安全工作区和较高的DI/DT性能。? 如要了解其他详细技术信息,请 联系支持部门。

F0240YH300 数据手册

 浏览型号F0240YH300的Datasheet PDF文件第1页浏览型号F0240YH300的Datasheet PDF文件第2页浏览型号F0240YH300的Datasheet PDF文件第3页浏览型号F0240YH300的Datasheet PDF文件第5页浏览型号F0240YH300的Datasheet PDF文件第6页浏览型号F0240YH300的Datasheet PDF文件第7页 
WESTCODE An IXYS Company  
Extra Fast Recovery Diode Types F0240Y#250 to F0240Y#300  
5.0 Reverse Recovery Loss  
The following procedure is recommended for use where it is necessary to include reverse recovery  
loss.  
From waveforms of recovery current obtained from a high frequency shunt (see Note 1) and reverse  
voltage present during recovery, an instantaneous reverse recovery loss waveform must be  
constructed. Let the area under this waveform be E joules per pulse. A new sink temperature can then  
be evaluated from:  
TSINK = TJ (MAX ) E   
Where k = 0.2314 (°C/W)/s  
k + f RthJK  
E = Area under reverse loss waveform per pulse in joules (W.s.)  
f = Rated frequency in Hz at the original sink temperature.  
RthJK = d.c. thermal resistance (°C/W)  
The total dissipation is now given by:  
W =W(original) + Ef  
(tot)  
NOTE 1 - Reverse Recovery Loss by Measurement  
This device has a low reverse recovered charge and peak reverse recovery current. When measuring  
the charge, care must be taken to ensure that:  
(a) AC coupled devices such as current transformers are not affected by prior passage of high  
amplitude forward current.  
(b) A suitable, polarised, clipping circuit must be connected to the input of the measuring  
oscilloscope to avoid overloading the internal amplifiers by the relatively high amplitude forward current  
signal.  
(c) Measurement of reverse recovery waveform should be carried out with an appropriate critically  
damped snubber, connected across diode anode to cathode. The formula used for the calculation of  
this snubber is shown below:  
Vr  
di  
CS   
dt  
R2 = 4  
Where: Vr = Commutating source voltage  
CS = Snubber capacitance  
R = Snubber resistance  
6.0 Snubber Components  
When selecting snubber components, care must be taken not to use excessively large values of  
snubber capacitor or excessively small values of snubber resistor. Such excessive component values  
may lead to device damage due to the large resultant values of snubber discharge current. If required,  
please consult the factory for assistance.  
Data Sheet. Types F0240Y#250 to F0240Y#300 Issue 1  
Page 4 of 12  
August, 2004  

与F0240YH300相关器件

型号 品牌 描述 获取价格 数据表
F02483-000 LITTELFUSE PTC Resettable Fuse, Surface Mount, ROHS COMPLIANT

获取价格

F0285B INFINEON Visible LED

获取价格

F02A125V10A LITTELFUSE MILITARY COMPONENTS FUSES

获取价格

F02A125V10AS COOPER Electric Fuse, Fast Blow, 10A, 250VAC, 200A (IR), Inline/holder

获取价格

F02A125V8A LITTELFUSE MILITARY COMPONENTS FUSES

获取价格

F02A250V1/100A LITTELFUSE MILITARY COMPONENTS FUSES

获取价格