Green
SURFACE MOUNT
REVERSE VOLTAGE – 600 Volts
SUPER FAST RECTIFIERS
FORWARD CURRENT – 3.0 Ampere
FEATURES
Glass passivated chip
SMB
Super fast switching for high efficiency
For surface mounted applications
Low forward voltage drop and high current capability
Low reverse leakage current
SMB
DIM
A
MIN
4.06
3.30
1.96
0.15
5.21
0.05
2.01
0.76
MAX
4.57
3.94
2.21
0.31
5.59
0.20
2.50
1.52
Qualified according to AEC-Q101 Rev_D
Available in “Green” Package: SMB
B
.
.
Lead-Free Finish; RoHS Compliant (Notes 1 & 2)
C
Halogen and Antimony Free. “Green” Device (Note 3)
D
E
MECHANICAL DATA
• Case: Molded plastic
• Case Material: Molding compound, UL Flammability
classification 94V-0,"Halogen-free".
F
G
H
• Polarity: Color band denotes cathode
• Weight: 0.003 ounces, 0.093 grams
All dimension in millimeter
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25°C ambient temperature unless otherwise specified.
PARAMETER
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
SYMBOL
VRRM
ES3JB
600
UNIT
V
V
V
A
VRMS
420
Maximum DC Blocking Voltage
VDC
600
Maximum Average Forward Rectified Current
@TL=110°C
I(AV)
3.0
Peak Forward Surge Current 8.3ms single half sine-wave
super imposed on rated load (JEDEC METHOD)
IFSM
VF
IR
100
A
V
Maximum forward Voltage at 3.0A DC
1.30
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@ TJ=25°C
@ TJ=125°C
10
500
uA
Maximum Reverse Recovery Time (Note 4)
Typical Reverse Recovery Time
trr
trr
35
30
45
ns
ns
pF
Typical Junction Capacitance (Note 5)
CT
RthJA
RthJL
RthJC
50
15
15
Typical Thermal Resistance (Note 6)
°C/W
Operating Temperature Range
Storage Temperature Range
TJ
-55 to + 150
-55 to + 150
°C
°C
TSTG
Note :
REV-1, Oct-2021, KSGB17
1. EU Directive 2002/95/EC (RoHS), 2011/65/EU (RoHS 2) & 2015/863/EU (RoHS 3) compliant. All applicable RoHS exemptions applied.
2. See https://www.diodes.com/quality/lead-free/ for more information about Diodes Incorporated’s definitions of Halogen- and Antimony-free, "Green" and Lead-free.
3. Halogen- and Antimony-free "Green” products are defined as those which contain <900ppm bromine, <900ppm chlorine (<1500ppm total Br + Cl) and <1000ppm antimony
compounds.
4. Reverse Recovery Test Conditions :IF=0.5A,IR=1.0A,IRR=0.25A.
5. Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
6. Thermal Resistance junction to Ambient, Lead and Case.