Reference Specifications
Ver.2.4
2
Product Name
PIR MOTION SENSOR “PaPIRs”
EKMB120611
Model No.
Page:
4.Characteristics
4-1 Detection Performance
Conditions for measuring: Ambient temperature=25℃(77゚F) Operating voltage=3VDC
Temperature
Value
Conditions concerning the target
difference
(Note1)
1.Movement speed: 1.0m/s
8℃(14.4゚F)
up to 17m
up to 12m
2.Target concept is human body
(Object size:Around 700×250mm)
Detection
Range
4℃(7.2゚F)
Note1:Depending on the temperature difference between the target and the surroundings,
detection range will change.
Value
62゚(±31゚)
62゚(±31゚)
128
Notes
Horizontal
Vertical
Detection
Area
Refer to the section 4-5.
Detection zones
4-2 Maximum Rated Values
Value
-0.3~4.5
Unit
Power Supply Voltage
VDC
-20~+60℃ (-4~+140゚F)
Usable Ambient Temperature
Do not use in a freezing or
condensation environment
Storage Temperature
-20~+70℃ (-4~+158゚F)
4-3 Electrical Characteristics
Conditions for Measuring: Ambient temperature:25℃(77゚F)
Symbol
Vdd
Iw
Min
2.3
-
Avg.
-
Max
4.0
Unit
VDC
μA
Special mention
Operating Voltage
Electrical Current Consumption
Output Current
-
1.9
-
3.0
Iout=0
Iout
-
100
μA
Vout≧Vdd-0.5
Output Voltage
Vout Vdd-0.5
-
-
VDC
s
-
-
Circuit Stability Time
Twu
-
25
210
(when voltage is applied)
Issued on Apr. 1st,2021