EE-SX3340/EE-SX4340
Safety Precautions
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the Sensor.
CAUTION
Precautions for Correct Use
This product is not designed or rated for ensuring
safety of persons either directly or indirectly. Do not
use it for such purposes.
Do not use the product in atmospheres or
environments that exceed product ratings.
This product is for surface mounting. Refer to
Soldering Information, Storage and Baking for
details.
Precautions for Safe Use
Dispose of this product as industrial waste.
Do not use the product with a voltage or current
that exceeds the rated range.
Applying a voltage or current that is higher than the rated range may
result in explosion or fire.
Do not miswire such as the polarity of the power
supply voltage.
Otherwise the product may be damaged or it may burn.
Do not short-circuit the load.
Otherwise explosion or burning may occur.
This product does not resist water. Do not use
the product in places where water or oil may be
sprayed onto the product.
Dimensions and Internal Circuit
(Unit: mm)
Photomicrosensor
EE-SX3340
EE-SX4340
(2×0.2)
2.5 mm dia. / 0.3 mm recess
(5)
(2×16°)
(1)
4
<Emitter>
(2)
(4)
(3)
<Detector>
8
Marking(Upper: model,
Lower: lot number)
(2×0.3)
4
0.2
Terminals are exposed in the
2
Terminals are exposed in the
end face of the board
end face of the board
A B
0.5 0.15
1.4
(2×30°)
1.5
0.34
0.7
1.5
1.5
4
5.5
1.4
Optical axis
2×R0.5
(0.4)
R0.3
R0.3
1
1
1
1
Cross sectional view
Cross sectional view
(0.4)
1
1
<Detector>
B-B
<Emitter>
A-A
1
2.8
A B
Aperture size (H × W)
Internal circuit
2.8
Top view
Emitter
Detector
(1)
(5)
1.04 × 1.4
1.4 × 0.5
Recommended soldering patterns
(4)
(3)
(2)
0.4
1
Terminal No.
Name
1
(1)
(2)
Anode
1
Cathode
0.4
Power supply
voltage
2
6
2
(3)
(4)
(5)
Output
ground
Unless otherwise specified, the tolerances are 0.15 mm.
3