EE-SX4320
Safety Precautions
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the Sensor.
CAUTION
Precautions for Correct Use
Do not use the product in atmospheres or
environments that exceed product ratings.
This product is for surface mounting. Refer to
Soldering Information, Storage and Baking for
details.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly. Do not
use it for such purposes.
Precautions for Safe Use
Do not use the product with a voltage or current
that exceeds the rated range.
Applying a voltage or current that is higher than the rated range may
result in explosion or fire.
Dispose of this product as industrial waste.
Do not miswire such as the polarity of the power
supply voltage.
Otherwise the product may be damaged or it may burn.
Do not short-circuit the load.
Otherwise explosion or burning may occur.
This product does not resist water. Do not use
the product in places where water or oil may be
sprayed onto the product.
Dimensions and Internal Circuit
(Unit: mm)
Photomicrosensor
EE-SX4320
Ejector pin, gate mark, or flat surface
2.0 mm dia. or 0.5 mm recess (MAX)
Emitter side
Detector side
(1)
(2)
(3)
(6)
(5)
(4)
5.1
Aperture size (H x W)
Emitter
Detector
Terminals are exposed
Terminals are exposed
in the end face of the board
in the end face of the board
Marking
(upper: model, lower: lot No.)
1.4×1.4
1×0.3
Optical axis
2 0.2 1.55
0.3 0.15
1.4
B
A
R0.3
1
R0.3
A
B
(0.4)
(0.4)
1
1
1
1
1
Cross section view B-B
(Emitter side)
Cross section view A-A
(Detector side)
2.8
2.8
Internal circuit
(1)
(6)
(5)
(2)
(3)
2
3.1
2
(4)
Terminal No.
Name
Anode
(1)
(2)(3)
(4)
Cathode
ground
Power supply
voltage
(5)
(6)
Unless otherwise specified, the tolerances are 0.2 mm.
Output