65/100/130 Watts
ECS Series
xppower.com
•
•
•
•
•
•
•
IT & Medical Safety Approvals
65/80/100 W - Convection-cooled Ratings
Class I & Class II Construction
Industry Standard 2”x 4”Package
<0.5 W No Load Input Power
Low Leakage Current
3 Year Warranty
Specification
Input
General
Efficiency
Isolation
• Up to 90% model dependent
Input Voltage
• 80-264 VAC (275 VAC ECS65)
(120-370 VDC), derate output power
<90 VAC, see derating curves
• 4000 VAC Input to Output, 2 x MOPP,
1500 VAC Input to Ground, 1 x MOPP,
500 VDC Output to Ground, 1 x MOPP
(1)
Input Frequency
Input Current
• 47-400 Hz
Switching Frequency
Power Density
• 65 KHz typical
• 65 W: 1.0/0.6 A typical at 115/230 VAC
100 W: 1.5/0.9 A typical at 115/230 VAC,
130 W: 1.9/1.1 A typical at 115/230 VAC
full load
• 40 A max at 230 VAC, cold start at 25 ˚C
• EN61000-3-2, class A
3
3
• 65 W: 7.7 W/in , 100 W: 10 W/in ,
3
130 W: 13 W/in
MTBF
• 65 W: 850 kHrs, 100 W: 834 kHrs,
130 W: 715 kHrs to MIL-HDBK-217F
at 25 ˚C, GB
Inrush Current
Power Factor
No Load Input Power • <0.5 W
Environmental
Operating Temperature • -20 ˚C (-40 ˚C, ECS130) to +70 ˚C derate
linearly from +50 ˚C at 2.5%/˚C to 50%
load at +70 ˚C.
Earth Leakage Current • 65/130 W: 260 µA at 264 VAC/60 Hz max
100 W: 230 µA at 264 VAC/60 Hz max
Input Protection
• Internal T3.15/T5 A/250 V fuse in line and
neutral
Cooling
• Convection & fan cooled ratings(see tables)
• 95% RH, non-condensing
• -40 ˚C to +85 ˚C
• 65-100 W: 3000 m, 130 W: 5000m
• 30 g pk, half sine, 6 axes
• 2 g rms, 5 Hz to 500 Hz, 3 axes
Operating Humidity
Storage Temperature
Operating Altitude
Shock
Output
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
• 12-48 VDC (see tables)
•
•
10%
1%
Vibration
• No minimum load required
• 1 s typical
• 50 ms
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level
Emissions
• EN55011/22 level B conducted
EN55011/22 level A radiated, level B
Suffix ‘-B’ models
• EN61000-3-2, class A
• EN61000-3-3
• EN61000-4-2, 6 kV Contact, 15 kV Air
Discharge, Perf Criteria A
• EN61000-4-3, level 3 Perf Criteria A
• EN61000-4-4, level 3 Perf Criteria A
• EN61000-4-5, installation class 3
Perf Criteria A
• EN61000-4-6, level 3 Perf Criteria A
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation.
• 16 ms min at 115 VAC
Drift
•
•
•
0.2% after 20 min warm up
0.5% max
1%
Line Regulation
Load Regulation
Over/Undershoot
Transient Response
Harmonic Currents
Voltage Flicker
ESD Immunity
• 5% typical
• 4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Radiated Immunity
EFT/Burst
Surge
Ripple & Noise
• 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overload Protection • 110-160%
Short Circuit Protection • Continuous trip and restart (hiccup mode)
Conducted Immunity
Dips & Interruptions
Temperature
Coefficient
• 0.05%/˚C
Safety Approvals
• IEC60950-1 CB report, CSA 22.2
No. 60950-1, UL60950-1, TUV EN60950-1
IEC60601-1 CB report, CSA 22.2
Notes
No. 60601-1, ANSI/AMMI ES60601-1,
TUV 60601-1, including risk management
1. Safety approvals cover frequency 47-63 Hz.
Equipment Protection • Class I & II (ECS65 Non ‘-B’ models,
Class
Class I only)