2-Wire Digital Thermometer and Thermostat

DS1721U/T,R 技术参数

是否无铅: 不含铅是否Rohs认证: 符合
生命周期:Active包装说明:TSSOP8,.19
Reach Compliance Code:compliantECCN代码:EAR99
HTS代码:8542.39.00.01Factory Lead Time:6 weeks
风险等级:1.36最大精度(摄氏度):1 Cel
主体宽度:3 mm主体高度:1.1 mm
主体长度或直径:3 mm外壳:PLASTIC
JESD-609代码:e3安装特点:SURFACE MOUNT
位数:12端子数量:8
最大工作电流:1.25 mA最高工作温度:125 °C
最低工作温度:-55 °C输出接口类型:2-WIRE INTERFACE
封装主体材料:PLASTIC/EPOXY封装等效代码:TSSOP8,.19
封装形状/形式:SQUARE电源:3/5 V
传感器/换能器类型:TEMPERATURE SENSOR,SWITCH/DIGITAL OUTPUT,SERIAL子类别:Other Sensors
最大供电电压:5.5 V最小供电电压:2.7 V
表面贴装:YES端子面层:Matte Tin (Sn)
端接类型:SOLDERBase Number Matches:1

DS1721U/T,R 数据手册

 浏览型号DS1721U/T,R的Datasheet PDF文件第2页浏览型号DS1721U/T,R的Datasheet PDF文件第3页浏览型号DS1721U/T,R的Datasheet PDF文件第4页浏览型号DS1721U/T,R的Datasheet PDF文件第6页浏览型号DS1721U/T,R的Datasheet PDF文件第7页浏览型号DS1721U/T,R的Datasheet PDF文件第8页 
DS1721  
The active state for the totem-pole output is programmable by the user. The power-up default of the  
DS1721 has TH=80°C, TL=75°C, and the output state active high. Refer to the “OPERATION-  
Programming” section for instructions in adjusting the thermostat setpoints and TCOM active state.  
THERMOSTAT OUTPUT OPERATION Figure 2  
OPERATION-Programming  
There are two areas of interest in programming the DS1721: the Configuration/Status register and the  
thermostat setpoints. All programming is done via the 2-wire interface using the protocols discussed in  
the “Command Set” section.  
Configuration/Status Register Programming  
The configuration/status register is accessed via the Access Config (ACh) function command. Writing to  
or reading from the register is determined by the R/ W bit of the 2-wire control byte (See “2-wire Serial  
Data Bus” section). Data is read from or written to the configuration register MSb first. The format of the  
register is illustrated below in Figure 3. The effect each bit has on DS1721 functionality is described  
below along with the power-up state of the bit and its ability to be read or written to. The entire register is  
volatile and will always power-up in the default state. Therefore, it is recommended that the user issue  
any configuration programming commands immediately after power is cycled, before any other  
commands are issued.  
CONFIGURATION/STATUS REGISTER Figure 3  
DONE  
MSb  
X
X
U
R1  
R0  
POL  
1SHOT  
LSb  
1SHOT = Temperature Conversion Mode. If 1SHOT is "1", the DS1721 will perform and store one  
temperature conversion upon reception of the Start Convert T (51h) command. If 1SHOT is "0", the  
DS1721 will continuously perform temperature conversions and store the last completed result in the  
Thermometer Register. The user has read/write access to the bit and the power-up default state is "0"  
(continuous mode).  
POL = TCOM Polarity Bit. If POL is "1", the active state of the TCOM output will be high. A "0" stored  
in this location sets the thermostat output to an active low state. The user has read/write access to the  
POL bit, and the power-up default state is "1" (active high).  
U = Undefined. This bit is used internally by the DS1721. It will be a "0" at power-up and will change to  
a "1" once the Start Convert T [51h] command is issued. This is a “Don’t Care” on a write; i.e. The  
DS1721 will ignore writes to this location.  
5 of 17  

与DS1721U/T,R相关器件

型号 品牌 描述 获取价格 数据表
DS1721U+T&R MAXIM Serial Switch/Digital Sensor, 12 Bit(s), 1Cel, Square, 8 Pin, Surface Mount, LEAD FREE, US

获取价格

DS1721U-T,R MAXIM 2-Wire Digital Thermometer and Thermostat

获取价格

DS1722 MAXIM Digital Thermometer with SPI/3-Wire Interface

获取价格

DS1722 DALLAS Digital Thermometer with SPI/3-Wire Interface

获取价格

DS1722 ADI 数字温度计,带有SPI/3线接口

获取价格

DS1722S MAXIM Digital Thermometer with SPI/3-Wire Interface

获取价格