Absolute Maximum Ratings (Note 2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Storage Temperature Range
−65˚C to +150˚C
Maximum Power Dissipation (Note 1) at 25˚C
Molded DIP Package
1207 mW
1042 mW
SO Package
Lead Temperature (Soldering, 4
sec.)
Note 1: Derate molded DIP package 9.7 mW/˚C above 25˚C; derate SO
Power Supply Voltage
Input Voltage Range
10V
30V
260˚C
±
Output Load Current
20 mA
1W
package 8.33 mW/˚C above 25˚C.
Power Dissipation (Note 3)
Operating Temperature Range
0˚C to +75˚C
Electrical Characteristics (Notes 3, 4, 5)
=
±
DS1489/DS1489A: The following apply for VCC 5.0V 1%, 0˚C ≤ TA ≤ +75˚C unless otherwise specified.
Symbol
Parameter
Conditions
Min
1.0
Typ
Max
1.5
Units
V
=
VTH
Input High Threshold Voltage
VOUT ≤ 0.45V,
DS1489
TA 25˚C
1.25
=
IOUT 10 mA
0.9
1.6
V
=
DS1489A
TA 25˚C
1.75
1.55
0.75
0.65
+3.6
−3.6
+0.43
−0.43
2.6
2.00
1.00
2.25
2.40
1.25
1.35
+8.3
−8.3
V
V
=
VTL
Input Low Threshold Voltage
Input Current
VOUT ≥ 2.5V,
TA 25˚C
V
=
IOUT −0.5 mA
V
=
IIN
VIN +25V
+5.6
−5.6
+0.53
−0.53
3.8
mA
mA
mA
mA
V
=
VIN −25V
=
VIN +3V
=
VIN −3V
=
=
VOH
Output High Voltage
IOUT −0.5 mA
VIN 0.75V
5.0
5.0
=
Input Open
2.6
3.8
V
=
=
VOL
ISC
ICC
Pd
Output Low Voltage
Output Short Circuit Current
Supply Current
VIN 3.0V, IOUT 10 mA
0.33
−3.0
14
0.45
V
=
VIN 0.75V
mA
mA
mW
=
VIN 5.0V
26
=
Power Dissipation
VIN 5.0V
70
130
Switching Characteristics
=
=
VCC 5V, TA 25˚C
Symbol
Parameter
Conditions
RL 3.9k, (Figure 1) (AC Test Circuit)
Min
Typ
Max
Units
=
tpd1
Input to Output “High”
Propagation Delay
Input to Output “Low”
Propagation Delay
Output Rise Time
Output Fall Time
28
85
ns
=
tpd0
RL 390Ω, (Figure 1) (AC Test Circuit)
20
50
ns
=
tr
tf
RL 3.9k, (Figure 1) (AC Test Circuit)
110
9
175
20
ns
ns
=
RL 390Ω, (Figure 1) (AC Test Circuit)
Note 2: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. Except for “Operating Temperature Range” they
are not meant to imply that the devices should be operated at these limits. The table of “Electrical Characteristics” provides conditions for actual device operation.
Note 3: Unless otherwise specified min/max limits apply across the 0˚C to +75˚C temperature range for the DS1489 and DS1489A.
Note 4: All currents into device pins shown as positive, out of device pins as negative, all voltages referenced to ground unless otherwise noted. All values shown
as max or min on absolute value basis.
=
Note 5: These specifications apply for response control pin open.
3