Specifications
Model
DRB120-12-3-Ax
DRB120-24-3-Ax
DRB240-24-3-Ax
DRB240-48-3-Ax
Output
Output Voltage Tolerance (100% load)
Switching Frequency (Output Converter)
Line Regulation
%
kHz
%
%
%
mV
mV
-
± 3 maximum
50 to 135. (Variable with input line and output load)
< 0.1
Load Regulation (No Parallel Mode)
Load Regulation (Parallel Mode)
Ripple & Noise (+25 to 70oC ambient)
Ripple & Noise (-25 to <+25oC ambient)
Minimum Load
< 1.1
< 3.8
10
< 0.4
< 2.9
10
< 0.6
< 3.1
10
< 0.2
< 2.8
20
20
30
40
80
No minimum load required
Maximum Load Capacitance
Overcurrent Protection (Auto Recovery)
Overvoltage Protection (Auto Recovery)
Overtemperature Protection
Remote Sense
uF
%
V
10,000
< 145
< 18
5,000
< 150
< 32
10,000
< 150
< 32
5,000
< 150
< 58
-
Yes. Auto recovery
-
None
Remote On/Off
-
Closed contact or <4V enables output
Closed contact relay when output voltage is >95%
Green LED indicates DC is OK
DC Good
-
Indicators
-
Parallel Operation
-
Front panel DIP switch to enable parallel droop mode current sharing.
Refer to technical datasheet when paralleling.
Environmental
Operating Temperature Nominal
°C
-25 to +55 full load, up to 70 with derating (see derating below)
Operating Temperature DeratingAbove 55°C W/°C
2
0.8
2.4
2.6
Storage Temperature
Humidity (Non condensing)
Cooling
°C
-40 to +85
%RH
95 (Operating & Storage)
Convection
-
m
Vac
-
Altitude
3,000 nominal, (6,000 maximum no UL certification)
Input to Output 3,510, Input to GND 2,210, Output to GND and signals 1,390
IEC 60068-2-6: 2g / 10 to 500Hz, 1 hour/direction X,Y,Z on DIN rail
IEC 60068-2-27, 30g / 11ms ±5ms, 3 x each axis on DIN rail
Withstand Voltage (For 1 minute)
Vibration (Non operating)
Shock (Non operating)
Other
-
Weight (Typ)
g
mm
Inches
-
660
660
780
780
Size (WxHxD)
55 x 129 x 138.2
2.17 x 5.08 x 5.44
Aluminum
Size (WxHxD)
Case Material
DIN Rail Type
-
Suitable for mounting on TS-35/7.5 or TS35/15 DIN Rails
MTBF - Telcordia SR-332 issue 4*
Warranty
Hours
Years
1,100,000
3
Notes
See website for detailed specifications, test methods and installation manual
(1) Minimum at 100% load
(2) Weighted average: 10%@Pout=20%, 50%@Pout=50%, 20%@Pout=80%, 20%@Pout=100%
*25°C ambient, full load.
3
DRB120/240-3 Series