づ
Fixed Inductors for Surface Mounting
面 定インダクタ
実装
け 用 固
D73LF/D73LC
D73F/D73C/D73CT
D75F
D7 Series Power Inductors
D7シリーズパワーインダクタ
Inductance Range: 1.0~100µH (D73LF, D73F, D73C), 1.2~100µH (D73LC), 4.7~470µH (D73CT),
1.0~470µH (D75F)
DIMENSIONS/外形寸法図
7.6Max.
2.0
5.1Max.
6.0
3.3
D73LF
D73LC
D73F/
D73C
D73CT
D75F
(Unit: mm)
3mm Max. height
D73F/D73C/D73CT; 3.5mm Max. height
D75F; 5.1mm Max. height
Note (*): D73LF/D73LC;
FEATURES/特ꢀ長
• Low-profile (7.6mm Max. square, 3.0, 3.5 and 5.1mm Max.
height).
• Available in magnetically shielded construction or
unshielded construction version.
• Suitable for large current.
• Ideal for a variety of DC-DC converter inductor applications.
• RoHS compliant.
• 低背(7.6mm角Max.、高さ、3.0、3.5および5.1mm Max.)
• 閉磁路又は開磁路構造が選択可能
• 大電流対応
• 各種機器のDC-DCコンバータ用インダクタに最適
• RoHS指令対応
MEASUREMENT CONDITION/測
定条件
(1) Inductance is measured with a LCR meter 4284A (Agilent
Technologies) or equivalent.
(2) DC resistance is measured with a Digital Multimeter
TR6871 (Advantest) or equivalent.
(3) Maximum allowable DC current is that which causes a
10% inductance reduction from the initial value, or coil
temperature to rise by 40°C, whichever is smaller.
(Reference ambient temperature 20°C)
(1) インダクタンスはLCRメータ4284A(Agilent Technologies)
または同等品により測定する。
(2) 直流抵抗はデジタルマルチメータTR6871(Advantest)ま
たは同等品により測定する。
(3) 最大許容電流は、直流重 畳電流を流した時インダクタンス
の値 が初期値 より10%減少する直流電流値 、または直流電
流により、コイルの温度が40℃上昇の何れか小さい値 です。
(周 囲温度20℃を基
準とする。)
Recommended patterns
推奨パターン図
2.0
2.0
4.4
continued on next page
次頁へ続く
(Unit: mm)