Additional Resources: Product Page
|
3D Model
|
PCB Footprint
date 09/03/2019
page 1 of 4
SERIES: CSXX05B │ DESCRIPTION: CURRENT SENSOR
FEATURES
• open loop
• bipolar
• detects current direction
• single channel
rated current (If)
linearity range1 (Im)
MODEL
(ARMS
±3
)
(APEAK
)
CS0305B
CS0505B
CS1005B
CS1505B
±3
±5
±5
±10
±15
±20
±10
±15
±20
CS2005B
Notes:ꢀ
1.ꢀImꢀisꢀtheꢀmaximumꢀpeakꢀcurrentꢀforꢀwhichꢀtheꢀoutputꢀvoltageꢀspecificationsꢀareꢀguaranteed,ꢀhoweverꢀtheꢀIfꢀRMSꢀratingꢀmustꢀnotꢀbeꢀexceeded.
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ2.ꢀAllꢀspecificationsꢀmeasuredꢀatꢀ25°C,ꢀRl=10ꢀkΩ,ꢀunlessꢀotherwiseꢀnoted.
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ3.ꢀItꢀisꢀrecommendedꢀtoꢀaddꢀaꢀ1ꢀμFꢀcapacitorꢀconnectedꢀbetweenꢀtheꢀcommonꢀterminalꢀ4ꢀandꢀtheꢀ+5ꢀVꢀterminalꢀ1ꢀtoꢀavoidꢀnoiseꢀproblems.
SPECIFICATIONS
parameter
conditions/description
min
typ
max
units
V
supplyꢀvoltageꢀ(Vcc)
max current consumption (Ic)
4.75
5.00
5.25
25
mA
atꢀ+If
at -If
4.47
0.47
4.50
0.50
4.53
0.53
V
V
outputꢀvoltageꢀ(Vo)
zeroꢀcurrentꢀoffsetꢀvoltageꢀ(Vr)
output voltage linearity4ꢀ(ΔKo)
response (tr)
after demagnetization
2.47
2.50
2.53
±0.5
V
%
μs
atꢀdi/dtꢀ=ꢀIf/μs
7
output voltage temperature
characteristics
±0.1
±1.5
%/°C
zeroꢀcurrentꢀoffsetꢀvoltageꢀ
characteristics
mV/°C
hysteresisꢀ(Vh)
atꢀ+Ifꢀtoꢀzeroꢀcurrent
8
mV
A
primary over current
withstand voltage
insulation resistance
operating temperature
storage temperature
safety approvals
flammabilityꢀrating
RoHS
forꢀmaximumꢀ50ꢀms,ꢀnoꢀdamage
between coil and each terminal for 1 minute
betweenꢀcoilꢀandꢀeachꢀterminalꢀatꢀ500ꢀVdc
10*If
2,000
Vac
MΩ
°C
500
-10
-30
75
90
°C
UL 508
UL94V-0
yes
Notes:ꢀ
4.ꢀDeductingꢀtheꢀvalueꢀofꢀhysteresisꢀandꢀoffsetꢀvoltage,ꢀcalculatedꢀbyꢀ(V/Vo)/(IfxI-1)x100%.
cui.com