V13
DIN RAIL Series
︳
40/60/100 W
att Single Output
Features
* Universal Input Range 90~264VAC
* Efficiency up to 90%
* Meets EN55022 and CISPR/FCC Class B
* Continuous Short Circuit Protection
* LED Indicator for Power ON
* Can be Installed on DIN rail TS-35/7.5 or 15
CFM40CXXX-DR Series
OUTPUT
RIPPLE &
NOISE
VOLTAGE
ACCURACY
OUTPUT
%EFF.
(Typ.)
LINE
LOAD
MODEL
VOLTAGE
REGULATION
REGULATION
CURRENT
CFM40C033-DR
CFM40C050-DR
CFM40C090-DR
CFM40C120-DR
CFM40C150-DR
CFM40C240-DR
CFM40C300-DR
CFM40C360-DR
CFM40C480-DR
3.3 V
5 V
6 A
6 A
50mV
1%
1%
1%
1%
1%
1%
1%
1%
70%
76%
84%
85%
85%
85%
86%
87%
87%
±
±
±
1%
0.5%
1%
±
±
±
1%
0.5%
1%
9 V
4.45 A
3.34 A
2.67 A
1.67 A
1.33 A
1.11 A
0.834 A
±
±
±
1%
0.5%
1%
12 V
15 V
24 V
30 V
36 V
48 V
±
±
±
1%
0.5%
1%
±
±
±
1%
0.5%
1%
±
±
±
1%
0.5%
1%
±
±
±
1%
0.5%
1%
±
±
±
1%
0.5%
1%
±
±
±
1%
0.5%
1%
CFM60CXXX-DR Series
OUTPUT
MODEL
VOLTAGE
RIPPLE &
NOISE
VOLTAGE
ACCURACY
LINE
LOAD
OUTPUT
%EFF.
(Typ.)
REGULATION
REGULATION
CURRENT
±
±
±
72%
77%
84%
85%
86%
86%
86%
88%
88%
CFM60C033-DR
CFM60C050-DR
CFM60C090-DR
CFM60C120-DR
CFM60C150-DR
CFM60C240-DR
CFM60C300-DR
CFM60C360-DR
CFM60C480-DR
3.3 V
5 V
8 A
8 A
50mV
1%
1%
1%
1%
1%
1%
1%
1%
1%
0.5%
1%
±
±
±
1%
0.5%
1%
±
±
±
9 V
6.67 A
5 A
1%
0.5%
1%
±
±
±
12 V
15 V
24 V
30 V
36 V
48 V
1%
0.5%
1%
±
±
±
4 A
1%
0.5%
1%
±
±
±
2.5 A
2 A
1%
0.5%
1%
±
±
±
1%
0.5%
1%
±
±
±
1.67 A
1.25 A
1%
0.5%
1%
±
±
±
1%
0.5%
1%
CFM101CXXX-DR Series
OUTPUT
MODEL
VOLTAGE
RIPPLE &
VOLTAGE
ACCURACY
LINE
LOAD
OUTPUT
%EFF.
PF
NOISE
REGULATION REGULATION
(Typ.)
(Typ.)
CURRENT
CFM101C120-DR
CFM101C150-DR
CFM101C200-DR
CFM101C240-DR
CFM101C480-DR
12 V
15 V
20 V
24 V
48 V
8.4 A
6.7 A
5 A
1%
1%
1%
1%
1%
87%
87%
88%
88%
90%
0.9
0.9
0.9
0.9
0.9
±
±
±
±
±
±
±
±
±
±
±
1%
0.5%
0.5%
0.5%
0.5%
0.5%
1%
1%
1%
1%
1%
±
1%
±
1%
4.2 A
2.1 A
±
1%
±
1%
1