For more information, please visit the product page.
date 12/11/2017
page 1 of 9
SERIES: CFM-50V │ DESCRIPTION: DC AXIAL FAN
FEATURES
• omniCOOLTM bearing system
• 50 x 50 mm frame
• multiple speed options for different cooling needs
• tachometer signal and rotation detect options available
• auto restart protection standard on all models
input
voltage
input
input
rated
air
static
noise4
MODEL
current1
power1
speed1
flow2
pressure3
rated
range
max
max
typ
max
(Vdc)
(Vdc)
(mA)
(W)
(RPM±15%)
(CFM)
11.0
13.8
11.0
13.8
7.7
(inch H2O)
0.11
0.15
0.11
0.15
0.07
0.12
0.17
0.23
0.31
0.17
0.23
(dBA)
CFM-5010V-043-260
CFM-5010V-052-300
CFM-5010V-143-260
CFM-5010V-155-310
CFM-5015V-132-154
CFM-5015V-138-201
CFM-5015V-150-290
CFM-5015V-161-330
CFM-5015V-172-381
CFM-5015V-247-290
CFM-5015V-258-330
5
3.5~6
3.5~6
98
179
58
0.49
0.90
0.70
0.98
0.40
0.51
0.65
1.00
1.53
0.82
1.23
4800
5800
4800
5800
3200
3800
5000
6100
7200
5000
6100
25.6
30.7
25.6
30.7
15.4
20.1
29.0
33.0
38.1
29.0
33.0
5
12
12
12
12
12
12
12
24
24
6~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
8~27.6
81
33
42
10.2
13.0
17.0
18.6
13.0
17.0
54
83
127
34
8~27.6
51
Notes:
1. At rated voltage, 25°C, 0 inch H20 static pressure, after 10 minutes
2. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H20 static pressure
3. As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow.
4. Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake.
5. All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
PART NUMBER KEY
CFM-5010V-043-260 - XX - CXX
Fan Signals
“blank” = no signals
11 = rotation detector signal
20 = tachometer signal
Base Number
Reserved for Custom
Configurations
cui.com