VER : A_1
update : 2015.03.16
DC-DC Brick
BR360 SERIES
360 Watts
DESCRIPTION
KEY FEATURES
Input under Voltage Protection
Over Current Protection (Hiccup Mode)
Short Circuit Protection (Hiccup Mode)
Over Voltage Protection (Hiccup Mode)
Over Temperature Protection (Self-recovery)
Remote ON/OFF Control
The BR360 series DC-DC converter are high-efficiency and power density
standard 1/2 brick isolated models. This series contain 6 modules, output
power from 100W to 360W, output voltage covering 3.3V, 5V, 12V and 48V four
levels. All models support primary ON/OFF control, remote Sense and Trim
function. This series which conform to the RoHS6 requirement can be used in
the fields of communication, data transmission and distributed power supply
system.
Remote Sense
Output Voltage Trim
Negative Logic:BR360-3.3S and BR360-12S
Positive Logic:BR360-48S
UL60950-1 and CSA C22.2 No. 60950-1-07
Meet UL94V-0 Flammability Requirements
RoHS6 Compliant
Size: 2.4 x 2.28 x 0.5 Inches
3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1.0 m/s (200 LFM), Vin = 48 V, Vout = 12 V , unless otherwise specified.
Model No.
Max Output Wattage (W)
BR360-3.3S
198W
BR360-12S
360W
BR360-48S
153.6W
Voltage (V.DC.)
48V (36~75V)
7.5A
11A
5.5A
Input
Current (A) (max)
(Vin = 0 - 75 V; Iout = 60 A)
(Vin= 36 V; Iout = 30 A)
(Vin= 36 V; Iout = 3.2 A)
No-Load Loss (W) (typ.)
Voltage Set Point (V.DC.)
Current (A) (max.)
4W
3.3V
60A
4.3W
12V
30A
1.2W
48V
3.2A
1%
1%
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
0.3%
0.5%
0.2%
0.3%
Output
150 mV
300 mV
300 mV
100% Load 92%
50% Load 93%
20% Load 90%
94.8%
95.6%
92.9%
93%
92.5%
89.5%
(Vin = 48 V; TA=25°C (77°F))
Over Power Protection
Over Current Protection
Over Voltage Protection
Hiccup mode
Hiccup mode
3.8~5V
14~16.5V
53~59V
Hiccup mode
Hiccup mode
Threshold:105~130°C / Hysteresis:5°C (min.)
Hiccup mode
Hiccup mode
Protection
Short Circuit Protection (max.)
Over Temperature Protection
Self-recovery (The values are obtained by measuring the temperature of the PCB bottom near
the thermal resistor.)
Isolation
Voltage (V.DC.)
1500 VDC (Basic Isolation and Functional Isolation)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
Environment
MTBF
1.5 Million Hours
(Airflow = 1.5 m/s (300 LFM); TA = 40°C (104°F); 80% load;
.Telcordia SR332 Method 1 case 3)
CE, UL, TUV
UL60950-1 and IEC/EN60950
Class B Requirements in FCC and EN55022 (After Connecting to an
External Filtering Circuit)
Safety
EMC
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Weight
Remote
On/Off Voltage
On/Off Current
2.4 x 2.28 x 0.5 Inches ( 61.0 x 57.9 x 13.0 mm ) Tolerance 0.5 mm
Physical
Other
100 g
67.6 g
82 g
Low level (V.DC.)
High level (V.DC.)
Low level (mA) (max.)
-0.7~1.2V
3.5~12V
1mA
-2~0.8V
3.5~18V
-0.7~1.2V
3.5~12V
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-