VER : A_1
update : 2015.03.16
DC-DC Brick
BR130 SERIES
36/60/72/100/132 Watts
DESCRIPTION
KEY FEATURES
Input under Voltage Protection
The BR130 series is a new generation isolated DC-DC converter that uses an
industry standard quarter-brick structure, and features high efficiency and
power density, operates from an input voltage range of 36 V to 75 V,
provides the rated output voltage of 1.2V / 1.5V / 1.8V / 2.5V / 3.3V and the
maximum output current of 30A / 40A.
Over Current Protection (Hiccup Mode)
Short Circuit Protection (Hiccup Mode)
Over Voltage Protection (Hiccup Mode)
Over Temperature Protection (Self-recovery)
Remote ON/OFF Control
BR130-1.2S / 1.5S / 1.8S / 2.5S / 3.3S
BR130-3.3SB
Remote Sense
Output Voltage Trim
UL60950-1 and CSA C22.2 No. 60950-1-07
Meet UL94V-0 Flammability Requirements
Rohs6 Compliant
Size: 2.28 x 1.45 x 0.38 Inches (others Model)
2.28 x 1.45 x 0.39 Inches (BR130-3.3S)
2.28 x 1.45 x 0.5 Inches (BR130-3.3SB)
3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.
BR130-
BR130-
BR130-
BR130-
BR130-
BR130-
3.3SB
Model No.
1.2S
36W
1.5S
60W
1.8S
72W
2.5S
100W
3.3S
132W
Max Output Wattage (W)
Voltage (V.DC.)
48V (36~75V)
Input
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage (V.DC.)
1.3A
1W
1.2V
3%
30A
2A
2W
1.5V
2.4A
2W
1.8V
3.5A
3.5W
2.5V
4.5A
3.6W
3.3V
Regulated Voltage Precision (max.)
Current (A) (max.)
40A
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
0.2%
0.2%
0.2%
0.3%
1%
1%
0.2%
0.3%
0.2%
0.3%
Output
100 mV
100 mV
100 mV
100 mV
120 mV
100% Load 89.5%
50% Load 89.5%
90.5%
91.5%
87%
91.5%
92%
92%
92%
93.5%
93.5%
87.5%
93.5%
93.5%
─
(Vin = 48 V; TA=25°C (77°F))
─
20% Load
87%
86.5%
Over Power Protection
Over Current Protection
Over Voltage Protection
Hiccup mode
Hiccup mode
1.4~2.0V
1.8~2.5V
(Hiccup mode)
2.2~3.0V
(Hiccup mode)
3.0~3.8V
(Hiccup mode)
3.9~4.7V
(Hiccup mode)
(Hiccup mode)
Protection
Short Circuit Protection (max.)
Over Temperature Protection
Hiccup mode
Threshold:115~135°C (typ.) / Hysteresis:5°C (min.)
Self-recovery (The values are obtained by measuring the temperature of the hottest power
component on the top surface of the converter.)
Isolation
Voltage (V.DC.)
1500 VDC (Functional Isolation)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
Environment
MTBF
2.5
1.5
1.5
1.5
1.5
2.5
Million Hr
Million Hr
Million Hr
Million Hr
Million Hr
Million Hr
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
BR130-3.3SB: 2.28 x 1.45 x 0.5 Inches ( 57.9 x 36.8 x 12.7 mm )
BR130-3.3S: 2.28 x 1.45 x 0.39 Inches ( 57.9 x 36.8 x 9.8 mm )
Safety
EMC
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Tolerance 0.5 mm
Physical
Other
others:
38 g
2.28 x 1.45 x 0.38 Inches ( 57.9 x 36.8 x 9.7 mm )
38 g 38 g 38 g 40 g
Weight
Remote
On/Off Voltage
On/Off Current
58 g
Low level (V.DC.)
High level (V.DC.)
Low level (mA) (max.)
-0.7~1.2V
3.5~12V
1mA
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-