Data Sheet
18V/500mA Output
Step-down DC/DC Converter(Non-isolated)
BP5226-18
Absolute Maximum Ratings
Dimensions (Unit :mm)
Parameter
Input voltage
Symbol
Limits
Unit
V
Conditions
Vi
DC
Operating temperature range
Storage temperature range
Topr
Tstg
°C
°C
Refer to derating curve
(Ambient temperature +
Maximum surface temperature
Maximum output current
Tcmax
Iomax
°C
the module self-heating) Tcmax
mApk
Electrical Characteristics
Derating Curve
Parameter
Input voltage range
Output voltage
Symbol Min.
Typ.
Max.
Conditions
DC
Vi=34V, Io=500mA
Vi=34V
Vi=20 to 46V, Io=500mA
Vi=34V, Io=0 to 500mA
Vi=34V, Io=500mA
SW1 OFF (VoOFF)
SW1 ON (VoON)
Unit
Derating Curve
600
500
400
Output current
Line regulation
Load regulation
Output ripple voltage
CTL pin OFF voltage
CTL pin ON voltage
CTL terminal pull-up resistance
Power conversion efficiency
300
Operation Range
200
100
0
-30 -20 -10
0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C
)
Conversion Efficiency
Conversion Efficiency
(Ta=25°C, Vi=34V)
100
Vi=34V, Io=500mA
80
60
40
Application Circuit
Function
Output terminal:Vo(18V)
CTL terminal
Power inductor terminal
Skip
Pin No.
20
0
1
2
BP5226-18
0
100
200
300 400
500
3
Output Current Io(mA)
4
Power inductor terminal
Skip
5
6
121110
7
5
3 2 1
Load Regulation
COMMON
7
Skip
8
Load Regulation
(Ta=25°C, Vi=12V)
20.0
Io
Skip
9
FUSE
Input terminal
N.C.
AC24V
10
11
12
18.0
16.0
14.0
12.0
10.0
8.0
L1
D1
Ctl
C2
Vo
Input terminal
C1
6.0
4.0
2.0
Be sure to use fuse for safety.
0
0
100 200 300 400 500 600 700 800
Output Current Io(mA)
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
Input terminal is 10 and 12.
External Component Specifications
FUSE: fuse
Use a quick-acting fuse (1.8A)
C1: Input capacitor
C2: Output capacitor
L1: Power inductor
Above 60V, current:above 1.0A
D1: Diode
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
2010.03 - Rev. B