Rated Current=66A Rated Voltage=520V AC

B84143V0066R127 数据手册

 浏览型号B84143V0066R127的Datasheet PDF文件第5页浏览型号B84143V0066R127的Datasheet PDF文件第6页浏览型号B84143V0066R127的Datasheet PDF文件第7页浏览型号B84143V0066R127的Datasheet PDF文件第9页浏览型号B84143V0066R127的Datasheet PDF文件第10页浏览型号B84143V0066R127的Datasheet PDF文件第11页 
Output filters  
B84143V*R127  
3-line sine-wave EMC output filters SineFormer  
Cautions and warnings  
Please read all warning and safety notes carefully before installing the filter and putting it into op-  
eration (see ). The same applies to the warning signs on the filter. Please ensure that the signs  
are not removed nor their legibility impaired by external influences.  
Death, serious bodily injury and substantial material damage to equipment may occur if the appro-  
priate safety measures are not carried out or the warnings in the text are not observed.  
Using according to the terms  
The filters may be used only for their intended application within the specified values in low-  
voltage networks in compliance with the instructions given in the data sheets and the data book.  
The conditions at the place of application must comply with all specifications for the filter used.  
Warning  
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such  
as planning, assembly, installation, operation, repair and maintenance. They must be provided  
with the corresponding documentation.  
Danger of electric shock. Filters contain components that store an electric charge. Dangerous  
voltages can continue to exist at the filter terminals for longer than five minutes even after the  
power has been switched off.  
The protective earth connections shall be the first to be made when the filter is installed and the  
last to be disconnected. Depending on the magnitude of the leakage currents, the particular  
specifications for making the protective earth connection must be observed.  
Impermissible overloading of the filter or filter, such as with circuits able to cause resonances,  
impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as  
cause substantial material damages (e.g. destruction of the filter housing).  
Filters must be protected in the application against impermissible exceeding of the rated cur-  
rents by overcurrent protective devices.  
In case of leakage currents >3.5 mA you shall mount the PE conductor stationary with the re-  
quired cross section before beginning of operation and save it against disconnecting. For leak-  
age currents IL 10 mA the PE conductor must have a KU value2) of 4.53); for leakage currents  
1)  
IL >10 mA the PE conductor must have a KU value of 64).  
Output chokes and output filters must be protected in the application against impermissible ex-  
ceeding of the component temperature.  
The converter output frequency must be within the specified range to avoid resonances and un-  
controlled warming of the output chokes and output filters.  
Because the product can become very hot during operation, there is the risk of burns if  
touched. The product can remain hot for some time after the power is switched off!  
1) IL = leakage current let-go  
2) The KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous  
body currents and excessive heating.  
3) A value of KU = 4.5 with respect to interruptions is attained with: a) permanently connected protective earth connection 1.5 mm2 and  
b) a protective earth connection 2.5 mm2 via connectors for industrial equipment (IEC 603092)  
4) KU = 6 with respect to interruptions is achieved for fixed-connection lines 10 mm2 where the type of connection and installation corre-  
spond to the requirements for PEN conductors as specified in relevant standards.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 8 of 13  

与B84143V0066R127相关器件

型号 品牌 描述 获取价格 数据表
B84143V0066R227 EPCOS 3-line filters Sine-wave output filter

获取价格

B84143V0066R227 TDK Rated Current=66A Rated Voltage=520V AC

获取价格

B84143V0066R229 TDK Rated Current=66A Rated Voltage=300/520V AC

获取价格

B84143V0075R227 EPCOS 3-line filters Sine-wave output filter

获取价格

B84143V0075R227 TDK Rated Current=75A Rated Voltage=520V AC

获取价格

B84143V0075R229 TDK Rated Current=75A Rated Voltage=300/520V AC

获取价格